{"product_id":"kidde-edwards-f-dact-f-series-dual-line-fire-alarm-dialer-modem-and-lcd-module","title":"Kidde Edwards F-DACT F-Series Dual-Line Fire Alarm Dialer Modem and LCD Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Kidde Edwards F-DACT is an F-Series multifunction Digital Alarm Communicator Transmitter designed to provide central-station event reporting, modem communications, and LCD display functions for compatible fire alarm control panels. Kidde Edwards part number F-DACT supports single- or dual-line reporting to Digital Alarm Communicator Receivers and enables local or remote computer access for panel programming, status monitoring, and event-history retrieval.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKidde Edwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF-DACT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Alarm Communicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Line DACT \/ Dialer \/ Modem \/ LCD Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral-Station Alarm Event Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Alarm Communicator Transmitter (DACT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTelephone Line Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Reporting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Single or Dual Reporting to Two DACRs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModem Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal and Remote Computer Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Upload\/Download, Panel Status and Event History\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Incoming Access \/ Callback Security\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDACT\/Modem\/LCD, Modem\/LCD, or LCD Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 65 mA Standby \/ 107 mA Active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-Pin Connector \/ Telephone Line Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–93% RH, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.5 in H × 8 in W × 0.75 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Monitoring, Remote Communications and Panel Programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.8 lb (0.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eF-DACT\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe F-DACT is an F-Series communications module that combines DACT, modem, and LCD interface capabilities in a compact panel-mounted assembly. As a communicator, it transmits alarm, supervisory, trouble, and other programmed system events over telephone lines to compatible Digital Alarm Communicator Receivers at monitoring facilities, with programmable single or dual reporting to two receivers. Its integrated modem provides local and remote computer connectivity for uploading or downloading panel configuration data and accessing system status and event history, while configurable callback security can restrict unauthorized remote programming. The module can be configured as a DACT\/modem\/LCD assembly, modem with LCD display, or LCD-only interface depending on the requirements of the compatible F-Series fire alarm installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDigital Alarm Communicator: Transmits programmed fire alarm system events to a compatible Digital Alarm Communicator Receiver at a monitoring facility.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDual-Line Capability: Supports two telephone lines for enhanced communications availability and supervised central-station reporting.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDual Receiver Reporting: Can be programmed for single or dual reporting to as many as two DACRs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated Modem: Provides communications for local and remote computer access to compatible F-Series control panels.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUpload\/Download Support: Allows compatible software to transfer panel configuration and programming data through the modem connection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemote Status Access: Supports retrieval of panel operating status and stored event history from connected computers.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLCD Display Function: Incorporates an LCD interface for local system information and operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple Operating Modes: Configurable as DACT\/modem\/LCD, modem\/LCD, or LCD-only depending on system requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCallback Security: Can require communication with a preprogrammed number before remote uploads or downloads are permitted.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e24 VDC Operation: Designed to operate from the compatible fire alarm panel's nominal 24 VDC power system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact Panel Module: Measures approximately 4.5 in high by 8 in wide by 0.75 in deep for internal system integration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eF-Series Integration: Designed as an optional communications and display module for compatible Edwards\/Kidde F-Series fire alarm control equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe F-DACT delivers the reliability and precision required for central-station fire alarm reporting, remote panel communications, programming access, and system status monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52805979930922,"sku":"F-DACT","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l500_ed95e26d-d884-42f8-98a0-75a46a63b3a6.jpg?v=1790805033","url":"https:\/\/iqelectro.com\/products\/kidde-edwards-f-dact-f-series-dual-line-fire-alarm-dialer-modem-and-lcd-module","provider":"IQElectro","version":"1.0","type":"link"}