{"product_id":"kidde-fenwal-74-200005-002-pegasys-multi-loop-rx-tx-communication-module","title":"Kidde-Fenwal 74-200005-002 PEGAsys Multi-Loop RX\/TX Communication Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Kidde-Fenwal 74-200005-002 is a PEGAsys\/FenwalNET 2000 RX\/TX module designed as the data interface between addressable field devices and the central control module in multi-loop fire alarm systems. It receives device status changes and manages bidirectional communication and power over compatible signaling circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 87.6812%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eKidde-Fenwal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003e74-200005-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eRX\/TX Communication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eReceiver\/Transmitter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003ePrinted Circuit Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003ePEGAsys \/ FenwalNET 2000 Multi-Loop Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eAddressable Field Device Data Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Input Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003e255 Addressable Devices per Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Output Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003e255 Addressable Devices per Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum RX\/TX Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003e8 per Multi-Loop I\/O Motherboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupported Circuit Styles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eNFPA Style 4, Style 6, Style 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eFactory Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eStyle 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eCircuit Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eOnboard Jumper Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eBidirectional Data and Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eIntelligent Multi-Loop Fire Alarm Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3544%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3965%; height: 19.5938px;\"\u003eApprox. 0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e 74-200005-002\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 74-200005-002 is a Kidde-Fenwal receiver\/transmitter module specifically configured for PEGAsys\/FenwalNET multi-loop control systems. Its circuitry interfaces intelligent field devices with the central control module through the system's multi-loop I\/O motherboard, which can accommodate up to eight RX\/TX modules. Each module can communicate with up to 255 addressable input devices and 255 addressable output devices while supporting NFPA Style 4, Style 6, or Style 7 supervision. The module is factory configured for Style 6 operation and can be adapted to the required circuit style through its onboard jumper configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-Loop RX\/TX Interface: Designed specifically for receiver\/transmitter operation in compatible multi-loop fire alarm control systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAddressable Device Communication: Transfers status and control data between field devices and the system central control module.\u003c\/li\u003e\n\u003cli\u003eHigh Device Capacity: Supports communication with up to 255 addressable input and 255 addressable output devices per RX\/TX module. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEight-Module Architecture: The multi-loop I\/O motherboard can accommodate as many as eight RX\/TX modules.\u003c\/li\u003e\n\u003cli\u003eStyle 4 Support: Allows compatible T-tapped or branched signaling line circuit arrangements.\u003c\/li\u003e\n\u003cli\u003eStyle 6 Support: Provides bidirectional transmission of data and power if an open occurs in the communication line.\u003c\/li\u003e\n\u003cli\u003eStyle 7 Support: Supports Style 7 supervised circuit arrangements when configured with appropriate isolation equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfigurable Jumpers: Onboard jumper settings allow the RX\/TX circuit configuration to be matched to the required wiring style. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 74-200005-002 delivers the reliability and precision required for multi-loop addressable device communication in intelligent fire alarm systems.\u003c\/p\u003e","brand":"Kidde-Fenwal","offers":[{"title":"Default Title","offer_id":52256092356906,"sku":"74-200005-002","price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_6b6db736-f194-4158-b575-315312ff00d7.webp?v=1786611273","url":"https:\/\/iqelectro.com\/products\/kidde-fenwal-74-200005-002-pegasys-multi-loop-rx-tx-communication-module","provider":"IQElectro","version":"1.0","type":"link"}