{"product_id":"kidde-fenwal-76-800020-001-aries-netlink-main-control-board-with-user-interface-display","title":"Kidde Fenwal 76-800020-001 ARIES NETLink Main Control Board with User Interface Display","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Kidde Fenwal 76-800020-001 is an ARIES NETLink multi-loop main control board designed to provide intelligent fire alarm system control, monitoring, and communication for commercial life safety installations. Integrating the main control board and user interface display, it supports multiple signaling loops, notification circuits, programmable relays, and communication interfaces for scalable addressable fire alarm systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 488.844px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eKidde Fenwal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003e76-800020-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eFire Alarm Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eARIES NETLink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eMain Control Board with User Interface Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eSupplied without enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSignaling Line Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003e2 SLC loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 39.1875px;\"\u003e\u003cstrong\u003eNotification Appliance Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 39.1875px;\"\u003e2 NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 39.1875px;\"\u003e\u003cstrong\u003eRemote Notification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 39.1875px;\"\u003e2 R-NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eProgrammable Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eUSB Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eRS-232 Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eIntelligent addressable fire alarm controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 39.1875px;\"\u003e\u003cstrong\u003eSystem Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 39.1875px;\"\u003eAlarm monitoring, supervisory monitoring, releasing logic, event logging, diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 39.1875px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 39.1875px;\"\u003eKidde Fire Systems ARIES NETLink fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eCompatible ARIES control panel enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38.1875px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 38.1875px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 38.1875px;\"\u003eCommercial addressable fire alarm and life safety systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4154%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2651%; height: 19.5938px;\"\u003eApproximately 3.5 lb (1.6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e76-800020-001\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 76-800020-001 is part of the Kidde Fire Systems ARIES NETLink series, engineered for advanced addressable fire alarm and emergency communication applications. Supplied without an enclosure, the assembly combines the main control board with an integrated user interface display, simplifying installation into compatible ARIES control panel cabinets. It supports two Signaling Line Circuits (SLCs), remote notification appliance circuits, standard NACs, programmable relay outputs, and multiple communication ports for system integration and diagnostics. Designed for high reliability and flexible system expansion, the controller provides intelligent device management, event processing, and network-ready operation for commercial fire protection systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eARIES NETLink Platform: Designed for intelligent addressable fire alarm system control.\u003c\/li\u003e\n\u003cli\u003eIntegrated Main Control Board: Combines system controller and user interface display in one assembly.\u003c\/li\u003e\n\u003cli\u003eDual SLC Loops: Supports two intelligent signaling line circuits for addressable devices.\u003c\/li\u003e\n\u003cli\u003eNotification Appliance Circuits: Includes two NACs for audible and visual notification appliances.\u003c\/li\u003e\n\u003cli\u003eRemote NAC Outputs: Provides two remote notification appliance circuits for distributed system layouts.\u003c\/li\u003e\n\u003cli\u003eProgrammable Relay Outputs: Three configurable relays for HVAC shutdown, elevator recall, and auxiliary control.\u003c\/li\u003e\n\u003cli\u003eUSB Interface: Supports local programming, diagnostics, and firmware maintenance.\u003c\/li\u003e\n\u003cli\u003eDual RS-232 Ports: Enables communication with compatible peripherals and service equipment.\u003c\/li\u003e\n\u003cli\u003eIntelligent Device Management: Continuously supervises connected addressable devices and system status.\u003c\/li\u003e\n\u003cli\u003eExpandable Architecture: Supports system growth through compatible ARIES NETLink expansion modules.\u003c\/li\u003e\n\u003cli\u003eEvent Monitoring: Records alarms, supervisory conditions, troubles, and operator actions.\u003c\/li\u003e\n\u003cli\u003eCommercial Reliability: Engineered for continuous operation in demanding life safety environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 76-800020-001 delivers the reliability and precision required for intelligent addressable fire alarm control and networked life safety applications.\u003c\/p\u003e","brand":"Kidde-Fenwal","offers":[{"title":"Default Title","offer_id":52141043777834,"sku":"76-800020-001","price":4099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_de26c98a-b76f-4483-800b-01567fe39aa0.webp?v=1785260374","url":"https:\/\/iqelectro.com\/products\/kidde-fenwal-76-800020-001-aries-netlink-main-control-board-with-user-interface-display","provider":"IQElectro","version":"1.0","type":"link"}