{"product_id":"kidde-fenwal-84-732001-902-aegis-2-0-fire-suppression-control-unit-nema-1-120-240-vac","title":"Kidde-Fenwal 84-732001-902 AEGIS 2.0 Fire Suppression Control Unit NEMA 1 120\/240 VAC","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Kidde-Fenwal 84-732001-902 is an AEGIS 2.0 fire suppression control unit designed to monitor, control, and release special hazard fire suppression systems in commercial and industrial facilities. Operating from a 120\/240 VAC power source, this NEMA 1 enclosed control panel provides flexible programming, reliable detection, and compatible operation with multiple suppression agent technologies.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKidde-Fenwal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Suppression Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84-732001-902\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Suppression Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAEGIS 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReleasing Fire Suppression Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClean Agent, CO₂, Wet Chemical, Dry Chemical, Foam, Foam-Water, Deluge, Pre-Action, Sprinkler, Halon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised initiating device circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised notification appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReleasing Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated supervised releasing circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated standby battery charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-programmable system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecial hazard fire suppression control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 18 lb (8.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e84-732001-902\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 84-732001-902 is part of the Kidde Fire Systems AEGIS 2.0 series, developed for small to mid-sized special hazard fire protection applications. Its steel NEMA 1 enclosure houses an intelligent releasing control panel capable of managing clean agent, CO₂, wet chemical, dry chemical, foam, deluge, pre-action, sprinkler, and Halon suppression systems. The control unit features programmable detection and releasing logic, supervised initiating and notification circuits, and integrated battery charging for dependable operation during power interruptions. Designed for simplified installation and maintenance, it offers expandable functionality and compatibility with a broad range of Kidde fire protection components.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-Hazard Compatibility: Supports clean agent, CO₂, wet chemical, dry chemical, foam, deluge, pre-action, sprinkler, and Halon systems.\u003c\/li\u003e\n\u003cli\u003eAEGIS 2.0 Platform: Advanced releasing control technology for special hazard fire protection.\u003c\/li\u003e\n\u003cli\u003eWide Input Voltage: Operates from 120\/240 VAC at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003eProgrammable Logic: Flexible configuration for detection, releasing, and notification functions.\u003c\/li\u003e\n\u003cli\u003eReleasing Circuits: Controls compatible fire suppression release devices.\u003c\/li\u003e\n\u003cli\u003eSupervised Detection Inputs: Continuously monitors initiating device circuits for proper operation.\u003c\/li\u003e\n\u003cli\u003eNotification Appliance Circuits: Supports audible and visual alarm devices.\u003c\/li\u003e\n\u003cli\u003eBattery Backup Support: Integrated charger maintains standby batteries for continued operation during AC power loss.\u003c\/li\u003e\n\u003cli\u003eNEMA 1 Enclosure: Durable indoor-rated steel cabinet finished in red.\u003c\/li\u003e\n\u003cli\u003eSystem Diagnostics: Provides status monitoring, fault indication, and maintenance information.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Designed for straightforward wiring, programming, and servicing.\u003c\/li\u003e\n\u003cli\u003eIndustrial Applications: Suitable for protecting electrical rooms, server rooms, control centers, machinery spaces, and other critical assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 84-732001-902 delivers the reliability and precision required for special hazard fire suppression control and releasing applications.\u003c\/p\u003e","brand":"Kidde-Fenwal","offers":[{"title":"Default Title","offer_id":52141025919274,"sku":"84-732001-902","price":2015.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l960_2aa20064-b769-4ad7-a335-8ef6647e7a7f.webp?v=1785258466","url":"https:\/\/iqelectro.com\/products\/kidde-fenwal-84-732001-902-aegis-2-0-fire-suppression-control-unit-nema-1-120-240-vac","provider":"IQElectro","version":"1.0","type":"link"}