{"product_id":"kidde-fenwal-89-100000-300-high-sensitivity-retrofit-smoke-detector-head","title":"Kidde-Fenwal 89-100000-300 High-Sensitivity Retrofit Smoke Detector Head","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Kidde-Fenwal 89-100000-300 is a high-sensitivity retrofit smoke detector head designed to replace original Fenwal ANALASER detector heads in existing fire detection systems. It provides sensitive smoke detection for applications requiring early identification of developing fire conditions and is designed for integration with compatible ANALASER systems.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"428\" style=\"width: 78.0727%; height: 338.039px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 19.5964px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 19.5964px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 19.5964px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 19.5964px;\"\u003eKidde-Fenwal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8958px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 19.8958px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 19.8958px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5339px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 35.5339px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 35.5339px;\"\u003e89-100000-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5339px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 35.5339px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 35.5339px;\"\u003eSmoke Detector Heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 19.5964px;\"\u003e\u003cstrong\u003eDetection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 19.5964px;\"\u003eHigh-Sensitivity Smoke Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5339px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 35.5339px;\"\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 35.5339px;\"\u003eFenwal AnaLASER II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1927px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 39.1927px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 39.1927px;\"\u003eReplacement of Original AnaLASER Detector Heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1927px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 39.1927px;\"\u003e\u003cstrong\u003eSensitivity Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 39.1927px;\"\u003e0.12%, 0.06%, 0.03%, and 0.015% obscuration\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 43.1771px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 43.1771px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 43.1771px;\"\u003eCompatible Fenwal AnaLASER Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.1901px;\"\u003e\n\u003ctd style=\"width: 40.1852%; height: 31.1901px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.585%; height: 31.1901px;\"\u003e1.0 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e89-100000-300\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 89-100000-300 is a retrofit detector head associated with the Fenwal ANA LASER II high-sensitivity smoke detection system. It is designed as a replacement for original ANALASER detector heads, allowing compatible installations to be maintained without replacing the complete detection system. The detector is identified as a high-sensitivity smoke detector and supports multiple sensitivity settings used by the ANALASER system. The part is discontinued by the manufacturer, making compatible surplus units relevant for maintaining existing installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eRetrofit Design: Provides a replacement detector head for compatible original ANALASER installations.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-Sensitivity Detection: Designed for early detection of low concentrations of smoke.\u003c\/li\u003e\n\u003cli\u003eANALASER Compatibility: Intended for use with existing Fenwal ANALASER detection systems.\u003c\/li\u003e\n\u003cli\u003eMultiple Sensitivity Levels: Associated with sensitivity settings of 0.12%, 0.06%, 0.03%, and 0.015% obscuration\/ft.\u003c\/li\u003e\n\u003cli\u003eExisting-System Replacement: Allows compatible installations to be maintained without replacing the complete detection system.\u003c\/li\u003e\n\u003cli\u003eDetector Head Format: Supplied as a detector head rather than a complete fire alarm control system.\u003c\/li\u003e\n\u003cli\u003eLegacy System Support: Suitable for maintaining older compatible Fenwal fire detection installations.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Part: The 89-100000-300 is identified as discontinued by the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Kidde-Fenwal 89-100000-300 delivers the sensitivity and compatibility required for maintaining existing high-sensitivity smoke detection systems.\u003c\/p\u003e","brand":"Kidde-Fenwal","offers":[{"title":"Default Title","offer_id":52587714183466,"sku":"89-100000-300","price":4099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_76e00189-3e03-443f-8920-c66e0aacd3ad.webp?v=1789211635","url":"https:\/\/iqelectro.com\/products\/kidde-fenwal-89-100000-300-high-sensitivity-retrofit-smoke-detector-head","provider":"IQElectro","version":"1.0","type":"link"}