{"product_id":"kidde-k-fsra10-fx-series-10-zone-led-remote-fire-alarm-annunciator","title":"Kidde K-FSRA10 FX-Series 10-Zone LED Remote Fire Alarm Annunciator","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Kidde K-FSRA10 is an FX-Series 10-zone remote LED annunciator designed to provide remote visual status indication for compatible 10-zone conventional fire alarm control panels. Kidde part number K-FSRA10 uses dedicated zone and system-status LEDs to identify alarm, supervisory, monitor, trouble, power, and ground-fault conditions from a convenient secondary location.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKidde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK-FSRA10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-Zone Remote LED Annunciator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Active Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Bi-Color Red\/Yellow LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Trouble Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Yellow LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower, Fire Alarm, Supervisory, Ground Fault, Trouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Zone Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervisory Zone Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYellow LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Zone Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashing Yellow LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Remote Annunciator Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Annunciator Bus Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 ft (305 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 AWG Untwisted, Non-Shielded Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 18.8–27.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLamp Test \/ Local Buzzer Silence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Reset \/ Signal Silence Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot Included; Available on K-FSRA10C Version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard North American 4-Inch-Square Electrical Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKidde 10-Zone Conventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSP1004RD \/ FX-10 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e793016052070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 lb (0.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eK-FSRA10\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe K-FSRA10 is an FX-Series remote annunciator specifically designed for use with compatible 10-zone Kidde fire alarm systems, including the FSP1004RD\/FX-10 platform. Its front panel provides ten red\/yellow bi-color zone-active LEDs, ten yellow zone-trouble LEDs, and dedicated indicators for power, fire alarm, supervisory, ground fault, and system trouble conditions. The annunciator communicates through the system remote annunciator bus and mounts to a standard North American 4-inch-square electrical box, with a surface-mount box available for installations where recessed mounting is impractical. Unlike the K-FSRA10C version, the standard K-FSRA10 is primarily an indication unit and does not provide the common Reset and Signal Silence controls found on the “C” model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e10-Zone Annunciation: Provides individual status indication for all ten zones of a compatible 10-zone fire alarm control panel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBi-Color Zone LEDs: Ten red\/yellow LEDs identify active alarm, supervisory, and monitor conditions by zone.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eZone Trouble Indicators: Ten separate yellow LEDs provide individual indication of zone trouble conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSystem Status Indicators: Dedicated LEDs display power, fire alarm, supervisory, ground fault, and general trouble status.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple Condition Display: Red indicates an active alarm zone, yellow indicates supervisory activity, and flashing yellow identifies an active monitor zone.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemote Annunciator Bus: Communicates with the host fire alarm panel through the dedicated serial remote annunciation interface.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtended Bus Wiring: The system remote annunciator bus supports cable runs up to approximately 1,000 ft (305 m) using specified wiring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLamp Test Function: Allows the annunciator LEDs to be illuminated for verification of indicator operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard Box Mounting: Designed for installation on a standard North American 4-inch-square electrical box.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurface-Mount Option: Can be installed using an available surface box where flush electrical-box mounting is unsuitable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact Remote Monitoring: Places detailed zone and system information at entrances, control rooms, or other locations away from the main panel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDedicated 10-Zone Compatibility: Intended specifically for compatible 10-zone panels rather than 5-zone configurations.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe K-FSRA10 delivers the reliability and precision required for remote zone and system-status annunciation in conventional commercial fire alarm installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52804556685610,"sku":"K-FSRA10","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_c5aca348-e4ba-4823-99a0-87a7af403421.webp?v=1790790498","url":"https:\/\/iqelectro.com\/products\/kidde-k-fsra10-fx-series-10-zone-led-remote-fire-alarm-annunciator","provider":"IQElectro","version":"1.0","type":"link"}