{"product_id":"kidde-mirbps6a-6-5a-remote-booster-power-supply-for-fire-systems","title":"Kidde MIRBPS6A 6.5A Remote Booster Power Supply for Fire Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Kidde MIRBPS6A is a 6.5 A remote booster power supply designed to expand available power for fire alarm notification and auxiliary life-safety circuits. It provides regulated 24 VDC power with four configurable notification appliance circuits that can be arranged as Class A or Class B circuits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKidde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIRBPS6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBooster Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Booster Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC or 220–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2 × 10 Ah in enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitoring and charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 A configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–93% non-condensing at 32°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eMIRBPS6A\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe MIRBPS6A belongs to the Kidde MIRBPS remote booster power supply series. It operates from 120 VAC or 220–240 VAC at 50\/60 Hz and provides a nominal 6.5 A maximum total output across its notification circuits. The unit includes battery monitoring and charging functions and supports up to two 10 Ah batteries within the enclosure. Its configurable outputs can provide notification appliance circuits or auxiliary 24 VDC power for compatible fire alarm, life-safety, security, and access-control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e6.5 A Output: Provides up to 6.5 A total output for compatible notification and auxiliary loads.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e24 VDC Supply: Provides nominal 24 VDC power for fire alarm and life-safety equipment.\u003c\/li\u003e\n\u003cli\u003eFour NAC Circuits: Provides four configurable notification appliance circuits.\u003c\/li\u003e\n\u003cli\u003eClass A\/B Configuration: Allows the NAC circuits to be configured as Class A or Class B.\u003c\/li\u003e\n\u003cli\u003eBattery Charging: Includes circuitry for monitoring and charging standby batteries.\u003c\/li\u003e\n\u003cli\u003eDual Input Monitoring: Supports two external controlling inputs for system activation.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power: Configurable outputs can provide auxiliary 24 VDC power for compatible equipment.\u003c\/li\u003e\n\u003cli\u003eGround Fault Detection: Includes selectable ground-fault monitoring for system supervision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe MIRBPS6A delivers the reliability and precision required for fire alarm notification, auxiliary power, and life-safety control systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Kidde","offers":[{"title":"Default Title","offer_id":52744894611754,"sku":"MIRBPS6A","price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_cad4a797-3468-47fb-8412-6eeab356f7c3.webp?v=1790340156","url":"https:\/\/iqelectro.com\/products\/kidde-mirbps6a-6-5a-remote-booster-power-supply-for-fire-systems","provider":"IQElectro","version":"1.0","type":"link"}