{"product_id":"kidde-sa-dact-dual-line-contact-id-fire-alarm-dialer-and-modem-communication-module","title":"Kidde SA-DACT Dual-Line Contact ID Fire Alarm Dialer and Modem Communication Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Kidde SA-DACT is a dual-line Digital Alarm Communicator Transmitter and modem designed to connect compatible fire alarm control panels with central monitoring stations over telephone networks. Kidde part number SA-DACT supports Contact ID event reporting, prioritized message transmission, dual telephone-line operation, and modem-based panel configuration and status access.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKidde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSA-DACT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Communicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Alarm Communicator Transmitter \/ Modem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Line Telephone Dialer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReporting Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTelephone Lines\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReporting Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle, Dual or Split Reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReporting Destinations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2 Account \/ Telephone Number Configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent Priority\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, Supervisory, Trouble, Disable, Test, Monitor, System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible Digital Alarm Communicator Receiver (DACR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModem Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Upload \/ Download Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModem Telephone Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Data Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration, History and Current Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Central-Station Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal Fire Alarm Control Panel Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSA-DACT\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe SA-DACT is a Kidde fire alarm communication module designed to transmit panel events to a compatible Digital Alarm Communicator Receiver (DACR) through the public switched telephone network. It monitors two telephone lines and can be configured for single, dual, or split reporting to two separate telephone numbers and account numbers for flexible central-station communication. Events are queued according to priority, with alarm conditions transmitted ahead of supervisory, trouble, disable, test, monitor, and general system events. Its integrated modem uses telephone line 1 to support remote uploading and downloading of compatible panel configuration data, event history, and current system status through the applicable PC configuration utility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDual-line communications: Supports two telephone lines for central-station fire alarm event reporting.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContact ID protocol: Transmits system events using the widely supported Contact ID digital reporting format.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCentral-station interface: Communicates with compatible Digital Alarm Communicator Receivers for monitored fire alarm applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePrioritized event reporting: Queues alarm, supervisory, trouble, disable, test, monitor, and system events according to priority.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible reporting modes: Supports single, dual, or split event reporting according to programmed system requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo reporting destinations: Can communicate with two different account numbers and telephone numbers.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated modem: Provides data communications for compatible fire alarm panel programming and system management.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemote configuration support: Allows compatible software to upload and download fire alarm control panel configuration information.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHistory retrieval: Supports access to stored panel event history through the modem connection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurrent status access: Allows compatible configuration software to obtain current panel operating information.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLine 1 modem operation: Uses telephone line 1 specifically for modem-based upload and download communications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePanel-mounted design: Installs as an internal communication module within supported Kidde fire alarm control equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe SA-DACT delivers the reliability and precision required for central-station event reporting, telephone-line supervision, and remote management of compatible fire alarm control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Kidde","offers":[{"title":"Default Title","offer_id":52794399097130,"sku":"SA-DACT","price":1125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_10.jpg?v=1790708763","url":"https:\/\/iqelectro.com\/products\/kidde-sa-dact-dual-line-contact-id-fire-alarm-dialer-and-modem-communication-module","provider":"IQElectro","version":"1.0","type":"link"}