{"product_id":"kidde-wk-897494-000-explosion-proof-control-head-24vdc-electric-and-cable-operated-for-co2-systems","title":"Kidde WK-897494-000 Explosion-Proof Control Head 24VDC Electric and Cable Operated for CO2 Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"417\"\u003eThe Kidde WK-897494-000 Explosion-Proof Control Head is a 24 VDC actuated device designed for reliable activation of fire suppression systems in hazardous environments. It supports both electric and cable-operated control, ensuring flexible deployment in industrial safety applications. Built to meet explosion-proof standards, it is suitable for use with CO2 and clean agent fire suppression systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 293.907px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eKidde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eFire \u0026amp; Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eWK-897494-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eControl Heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eExplosion-Proof Control Head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eActuation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eElectric and Cable Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eUL1203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eHazardous Location Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eClass I Groups C \u0026amp; D; Class II Groups E, F \u0026amp; G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eCO2 fire suppression systems; Clean agent systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eExplosion-proof housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eSystem-integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003eSystem activation control head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7222%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0585%; height: 19.5938px;\"\u003e2.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About WK-897494-000\u003c\/h4\u003e\n\u003cp data-start=\"419\" data-end=\"1064\"\u003eThe WK-897494-000 is an explosion-proof control head engineered for integration into Kidde fire suppression systems, particularly in hazardous locations requiring strict safety compliance. It is designed to operate with both electrical signals and manual cable actuation, providing redundancy and operational flexibility. The unit is UL1203 certified for Class I Groups C \u0026amp; D and Class II Groups E, F \u0026amp; G environments, ensuring safe use in areas with flammable gases, vapors, or combustible dust. Commonly used with CO2 systems and as a spare component for clean agent systems, it delivers dependable activation performance in critical fire protection setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion-Proof Certification: UL1203 rated for Class I Groups C \u0026amp; D and Class II Groups E, F \u0026amp; G hazardous locations\u003c\/li\u003e\n\u003cli\u003eDual Activation Method: Supports both electric (24 VDC) and cable-operated actuation\u003c\/li\u003e\n\u003cli\u003eFire Suppression Compatibility: Designed for CO2 systems and compatible with clean agent systems\u003c\/li\u003e\n\u003cli\u003eHazardous Area Operation: Suitable for environments with flammable gases and combustible dust\u003c\/li\u003e\n\u003cli\u003eReliable Actuation: Ensures consistent system activation in emergency conditions\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Construction: Built for durability in demanding safety applications\u003c\/li\u003e\n\u003cli\u003eFlexible Installation: Can be integrated into various suppression system configurations\u003c\/li\u003e\n\u003cli\u003eSpare Part Utility: Ideal for maintenance and replacement in existing systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe WK-897494-000 delivers the reliability and precision required for explosion-proof fire suppression system activation in hazardous industrial environments.\u003c\/p\u003e","brand":"Kidde","offers":[{"title":"Default Title","offer_id":51273330589994,"sku":"WK-897494-000","price":3219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l960_c8a8ec40-c23d-4ffa-afcb-b5c07acf8d34.webp?v=1773940853","url":"https:\/\/iqelectro.com\/products\/kidde-wk-897494-000-explosion-proof-control-head-24vdc-electric-and-cable-operated-for-co2-systems","provider":"IQElectro","version":"1.0","type":"link"}