{"product_id":"ls-g4f-rd2a-temperature-input-module-reliable-delivery","title":"LS Industrial Systems G4F-RD2A 4-Channel 12-Bit RTD Temperature Input Module for GM4 \u0026 MASTER-K PLC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"417\"\u003eThe LS Industrial Systems G4F-RD2A is a 4-channel RTD temperature input module designed for precise thermal monitoring in PLC-based control systems. This module processes signals from Pt100 RTD sensors with 12-bit resolution, ensuring accurate and stable temperature measurements. It is engineered for integration with GLOFA GM4 and MASTER-K 300S PLC platforms in industrial automation environments.\u003c\/p\u003e\n\u003cp data-start=\"419\" data-end=\"1008\"\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 98.0073%; height: 264.719px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003eLS Industrial Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003ePLCs\/Machine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003eG4F-RD2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003ePLC Input\/Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003eG4F-RD2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003eRTD (Resistive Temperature Detector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible RTD Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003ePt100 (JIS C1640-1989, DIN 43760-1980)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003e-200.0°C to 600.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eDigital Output Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003e0 to 16,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible PLC Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 19.5938px;\"\u003eGLOFA GM4, MASTER-K 300S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 35.808%; height: 10px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9694%; height: 10px;\"\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About G4F-RD2A\u003c\/h4\u003e\n\u003cp data-start=\"419\" data-end=\"1008\"\u003eThe G4F-RD2A is a temperature input module from LS Industrial Systems, developed for high-accuracy data acquisition in programmable logic controller systems. It is built to accept resistive temperature detector (RTD) inputs, specifically supporting Pt100 sensors compliant with JIS and DIN standards. The module features four independent input channels, enabling simultaneous multi-point temperature monitoring in industrial processes. Designed for compatibility with GLOFA GM4 and MASTER-K 300S series PLCs, it is commonly used in manufacturing, process control, and thermal management applications requiring reliable and consistent measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2029\" data-start=\"1126\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1879\" data-start=\"1036\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2324\" data-start=\"1345\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"964\" data-end=\"1727\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1807\" data-start=\"1042\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"994\" data-end=\"1763\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1253\" data-end=\"2155\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1090\" data-end=\"1767\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1128\" data-end=\"1917\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2014\" data-start=\"1175\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1842\" data-start=\"1084\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1877\" data-start=\"1111\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1690\" data-start=\"1018\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1129\" data-end=\"1879\"\u003e\n\u003cli data-section-id=\"xup4bl\" data-start=\"1129\" data-end=\"1234\"\u003e4-Channel Input Capability: Allows simultaneous monitoring of four independent RTD temperature points\u003c\/li\u003e\n\u003cli data-section-id=\"1k8l4tb\" data-start=\"1235\" data-end=\"1330\"\u003e12-Bit Resolution: Provides accurate digital conversion for precise temperature measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1ksw73y\" data-start=\"1331\" data-end=\"1428\"\u003eWide Temperature Range: Measures from -200.0°C to 600.0°C for diverse industrial applications\u003c\/li\u003e\n\u003cli data-section-id=\"mlgzjq\" data-start=\"1429\" data-end=\"1531\"\u003ePt100 Sensor Compatibility: Supports standard RTD types per JIS C1640 and DIN 43760 specifications\u003c\/li\u003e\n\u003cli data-section-id=\"17befuh\" data-start=\"1532\" data-end=\"1617\"\u003eDigital Output Scaling: Outputs data in a range of 0 to 16,000 for PLC processing\u003c\/li\u003e\n\u003cli data-section-id=\"7nef03\" data-start=\"1618\" data-end=\"1705\"\u003ePLC Integration: Designed for seamless use with GLOFA GM4 and MASTER-K 300S systems\u003c\/li\u003e\n\u003cli data-section-id=\"1xwri3n\" data-start=\"1706\" data-end=\"1800\"\u003eStable Signal Processing: Ensures consistent readings in demanding industrial environments\u003c\/li\u003e\n\u003cli data-section-id=\"eyk9th\" data-start=\"1801\" data-end=\"1879\"\u003eCompact Module Design: Facilitates efficient installation within PLC racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1881\" data-end=\"2028\"\u003eThe G4F-RD2A delivers the reliability and precision required for multi-channel temperature monitoring and control in industrial automation systems.\u003c\/p\u003e","brand":"LS Industrial Systems","offers":[{"title":"Default Title","offer_id":51308338512170,"sku":"G4F-RD2A","price":859.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_479070cb-7166-43af-b291-ad13722e9d85.webp?v=1774775260","url":"https:\/\/iqelectro.com\/products\/ls-g4f-rd2a-temperature-input-module-reliable-delivery","provider":"IQElectro","version":"1.0","type":"link"}