{"product_id":"megger-mit1025-us-10kv-20-tω-insulation-resistance-tester","title":"Megger MIT1025-US 10kV 20 TΩ Insulation Resistance Tester","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Megger MIT1025-US is a 10 kV insulation resistance tester designed for diagnostic testing and condition assessment of high-voltage electrical equipment. It measures insulation resistance up to 20 TΩ and supports IR, PI, DAR, DD, step voltage, and ramp testing for applications including power cables, motors, generators, transformers, and bus systems.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMegger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIT1025-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation Resistance Testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Voltage Insulation Resistance Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V, 500 V, 1 kV, 2.5 kV, 5 kV, 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVariable Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 V Steps from 50 V to 1 kV; 25 V Steps Above 1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIR, PI, DAR, DD, SV, Ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltmeter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30–660 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5% up to 1 TΩ at 5 kV and 2 TΩ at 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85–265 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRechargeable Battery \/ Line Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Battery Charge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.5 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital\/Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-20°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About MIT1025-US\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe MIT1025-US is a Megger 10 kV insulation resistance tester built for high-voltage electrical maintenance, commissioning, and diagnostic testing. Its portable dual-case construction combines fire-retardant protection with a rugged enclosure, while flexible silicone test leads support safe measurement according to IEC 61010-31:2008 requirements. The instrument provides selectable test voltages up to 10 kV, insulation resistance measurements up to 20 TΩ, a dedicated 30–660 V voltmeter function, and diagnostic modes including PI, DAR, DD, SV, and ramp testing. It can operate from its rechargeable battery or line power and includes advanced memory with time\/date stamping for recording and trending test results.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e10 kV Test Capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Provides insulation test voltages up to 10 kV for high-voltage electrical equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e20 TΩ Measurement Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Measures high insulation resistance values for installation testing and long-term condition trending.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMultiple Diagnostic Tests\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Supports timed IR, PI, DAR, DD, step voltage, and ramp testing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDedicated Voltmeter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Measures 30–660 V and provides frequency measurement for checking induced or present voltage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCAT IV 600 V Safety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: All terminals are rated CAT IV 600 V for use in demanding electrical environments.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh Measurement Accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Provides ±5% accuracy up to 1 TΩ at 5 kV and 2 TΩ at 10 kV.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRapid Battery Charging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Full battery charging takes approximately 2.5 hours, with a 30-minute charge providing approximately one hour of testing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdvanced Test Memory\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: Stores measurement information with time and date stamps for test documentation and trending.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003eMIT1025-US delivers the reliability and precision required for insulation diagnostics and condition assessment of high-voltage electrical equipment.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e","brand":"Megger","offers":[{"title":"Default Title","offer_id":52645559173418,"sku":"MIT1025-US","price":9779.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/717jsSFSSmL._SX425.jpg?v=1790105274","url":"https:\/\/iqelectro.com\/products\/megger-mit1025-us-10kv-20-t%cf%89-insulation-resistance-tester","provider":"IQElectro","version":"1.0","type":"link"}