{"product_id":"mircom-mix-dh3100-intelligent-duct-detector-ready-to-ship","title":"Mircom MIX-DH3100 Alpha Intelligent Duct Smoke Detector Photoelectric Addressable","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"19\" data-end=\"508\"\u003eThe Mircom MIX-DH3100 is an intelligent low-flow duct smoke detector designed for use in 2-wire analog addressable fire alarm systems. It utilizes a photoelectric sensing chamber to detect smoke within HVAC ductwork, providing early warning of fire conditions in air handling systems. The device is suitable for commercial and industrial installations requiring reliable duct-based smoke detection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eMircom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eMIX-DH3100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eDuct Smoke Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003ePhotoelectric Analog Addressable Duct Smoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e17–28 VDC (24 VDC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e#12–#22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eAir Velocity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e100–4000 ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eLED Alarm on Sensor Head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e10% to 85% RH Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003ePhotoelectric Optical Sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e2-Wire Analog Addressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003eHVAC Duct Smoke Detection Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.4942%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2866%;\"\u003e 2.0 lb (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eMIX-DH3100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe MIX-DH3100 is part of Mircom’s Alpha intelligent detector series designed for addressable fire alarm networks. It operates on a 17–28 VDC supply and communicates with compatible fire alarm control panels using analog addressable signaling. The detector is engineered for low-flow duct applications and is capable of monitoring a wide range of air velocities within HVAC systems. Its integrated LED indicator provides local alarm status, while its sensor head is optimized for stable photoelectric detection in varying environmental conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1341\" data-end=\"2149\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1163\" data-end=\"1902\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1885\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1126\" data-end=\"1911\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1221\" data-end=\"1962\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1145\" data-end=\"1838\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1060\" data-end=\"1738\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1152\" data-end=\"1867\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1139\" data-end=\"1929\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1227\" data-end=\"1992\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1152\" data-end=\"1948\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1061\" data-end=\"1796\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1039\" data-end=\"1802\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1075\" data-end=\"1785\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1131\" data-end=\"1905\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1130\" data-end=\"1817\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1161\" data-end=\"1924\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1083\" data-end=\"1733\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1195\" data-end=\"1934\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1052\" data-end=\"1790\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1246\" data-end=\"1963\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1165\" data-end=\"1867\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1108\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1217\" data-end=\"1850\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"1957\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1897\" data-start=\"1154\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1830\" data-start=\"1150\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1854\" data-start=\"1180\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1924\" data-start=\"1213\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1876\" data-start=\"1163\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1952\" data-start=\"1278\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1951\" data-start=\"1239\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1954\" data-start=\"1269\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1931\" data-start=\"1230\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1830\" data-start=\"1181\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1832\" data-start=\"1151\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1886\" data-start=\"1192\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1717\" data-start=\"1097\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1849\" data-start=\"1211\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1910\" data-start=\"1207\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1728\" data-start=\"1135\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1876\" data-start=\"1265\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1789\" data-start=\"1124\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1848\" data-start=\"1151\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1728\" data-start=\"1107\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1841\" data-start=\"1152\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1981\" data-start=\"1317\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2199\" data-start=\"1315\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1853\" data-start=\"1099\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1900\" data-start=\"1262\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1933\" data-start=\"1220\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1894\" data-start=\"1200\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1923\" data-start=\"1096\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1894\" data-start=\"1175\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1337\" data-end=\"2268\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1164\" data-end=\"1929\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"995\" data-end=\"1753\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1211\" data-end=\"1882\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"984\" data-end=\"1577\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1110\" data-end=\"1875\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1142\" data-end=\"1905\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1200\" data-end=\"1974\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1131\" data-end=\"1869\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1196\" data-end=\"1951\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1154\" data-end=\"1760\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1210\" data-end=\"2015\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1111\" data-end=\"1866\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1013\" data-end=\"1763\"\u003e\n\u003cli data-section-id=\"1bl3lhz\" data-start=\"1013\" data-end=\"1117\"\u003ePhotoelectric Detection: Uses optical sensing technology for reliable smoke detection in duct airflow.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sqfzmc\" data-start=\"1118\" data-end=\"1214\"\u003eAnalog Addressable Operation: Communicates directly with compatible fire alarm control panels.\u003c\/li\u003e\n\u003cli data-section-id=\"rnutog\" data-start=\"1215\" data-end=\"1303\"\u003eWide Air Velocity Range: Operates effectively from 100 to 4000 ft\/min in HVAC systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1a39wao\" data-start=\"1304\" data-end=\"1389\"\u003eLow-Flow Duct Design: Optimized for stable performance in low-airflow environments.\u003c\/li\u003e\n\u003cli data-section-id=\"1xe3feq\" data-start=\"1390\" data-end=\"1473\"\u003eLED Alarm Indicator: Provides clear local visual alarm status on the sensor head.\u003c\/li\u003e\n\u003cli data-section-id=\"qxkt3l\" data-start=\"1474\" data-end=\"1568\"\u003eFlexible Wiring Support: Compatible with #12 to #22 AWG wiring for installation flexibility.\u003c\/li\u003e\n\u003cli data-section-id=\"ki00pf\" data-start=\"1569\" data-end=\"1681\"\u003eEnvironmental Stability: Designed to operate in 0°C to 60°C temperature range and up to 85% RH non-condensing.\u003c\/li\u003e\n\u003cli data-section-id=\"18djlrs\" data-start=\"1682\" data-end=\"1763\"\u003e24 VDC Nominal Operation: Standard low-voltage fire alarm system compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1765\" data-end=\"1908\"\u003eThe MIX-DH3100 delivers the reliability and precision required for intelligent duct smoke detection in commercial HVAC fire protection systems.\u003c\/p\u003e","brand":"Mircom","offers":[{"title":"Default Title","offer_id":52035377955114,"sku":"MIX-DH3100","price":527.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/MIX-DH3100.png?v=1783089426","url":"https:\/\/iqelectro.com\/products\/mircom-mix-dh3100-intelligent-duct-detector-ready-to-ship","provider":"IQElectro","version":"1.0","type":"link"}