{"product_id":"notifier-amps-24e-addressable-24vdc-power-supply-and-battery-charger","title":"Notifier AMPS-24E Addressable 24VDC Power Supply and Battery Charger","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Notifier AMPS-24E is an addressable power supply and battery charger designed to provide supervised 24 VDC power distribution for NOTIFIER fire alarm control systems. It supports up to three 24 VDC outputs, programmable charging capabilities, and integration with NFS-3030, NFS2-3030, and NCA-2 systems. The module is used to provide reliable system power, battery backup management, and auxiliary power for life safety installations.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAMPS-24E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Power Supply and Battery Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFS-3030, NFS2-3030, NCA-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan® and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DC Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 0.5 A and 5 VDC @ 0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 AH to 200 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable charging current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated Signaling Line Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Type B connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC loss detection with delay reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrownout detection, battery supervision, charger monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrouble Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally open dry contacts or open-collector input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAB-4 Series, EQ Cabinet Series, BB-25, BB-100, BB-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm system power expansion and backup power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 5.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eAMPS-24E\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"487\" data-end=\"1117\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe AMPS-24E is part of the NOTIFIER addressable power supply family, developed for advanced fire alarm control panel installations requiring monitored power expansion. The unit provides isolated SLC communication, configurable battery charging from 7 AH to 200 AH batteries, and supervised auxiliary outputs for connected system devices. It is designed for installation in CAB-4 Series, EQ Series, and compatible battery backbox enclosures used with NOTIFIER control equipment. The power supply supports FlashScan® and CLIP operating modes, allowing flexible integration with existing and newer NOTIFIER fire alarm architectures.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1119\" data-end=\"1134\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1136\" data-end=\"2458\"\u003e\n\u003cli data-start=\"1136\" data-end=\"1272\"\u003eAddressable Power Supply: Communicates directly with NFS-3030 and NFS2-3030 fire alarm control panels for supervised power management.\u003c\/li\u003e\n\u003cli data-start=\"1273\" data-end=\"1397\"\u003eDual Protocol Support: Operates in FlashScan® or CLIP mode for compatibility with multiple NOTIFIER system configurations.\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1510\"\u003eMultiple 24 VDC Outputs: Provides up to three regulated 24 VDC power outputs for connected fire alarm devices.\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1615\"\u003eBattery Charging Capability: Supports selectable charging current for 7 AH to 200 AH backup batteries.\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1734\"\u003eIsolated SLC Interface: Provides electrically isolated signaling line communication for improved system reliability.\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1839\"\u003eAuxiliary Power Outputs: Includes secondary 24 VDC and 5 VDC auxiliary outputs for system peripherals.\u003c\/li\u003e\n\u003cli data-start=\"1840\" data-end=\"1945\"\u003eBattery Supervision: Continuously monitors battery condition and charger operation for fault reporting.\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"2042\"\u003eAC Loss Monitoring: Detects AC power loss and supports configurable delay reporting functions.\u003c\/li\u003e\n\u003cli data-start=\"2043\" data-end=\"2144\"\u003eBrownout Detection: Identifies reduced input voltage conditions to help prevent unstable operation.\u003c\/li\u003e\n\u003cli data-start=\"2145\" data-end=\"2246\"\u003eUSB Programming Interface: Includes a Type B USB connector for configuring installation parameters.\u003c\/li\u003e\n\u003cli data-start=\"2247\" data-end=\"2356\"\u003eTrouble Bus Input: Supports normally open dry contacts and open-collector circuits for external monitoring.\u003c\/li\u003e\n\u003cli data-start=\"2357\" data-end=\"2458\"\u003eFlexible Mounting Options: Compatible with CAB-4, EQ Cabinet, BB-25, BB-100, and BB-200 enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2460\" data-end=\"2604\"\u003eThe AMPS-24E delivers the reliability and precision required for supervised fire alarm power distribution and emergency backup power management.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52130636857642,"sku":"AMPS-24E","price":1112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/NF-PW08-0428.jpg?v=1785091237","url":"https:\/\/iqelectro.com\/products\/notifier-amps-24e-addressable-24vdc-power-supply-and-battery-charger","provider":"IQElectro","version":"1.0","type":"link"}