{"product_id":"notifier-lcm-320-onyx-addressable-slc-loop-control-module","title":"Notifier LCM-320 ONYX Addressable SLC Loop Control Module","description":"\u003ch4 data-start=\"0\" data-end=\"14\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003eThe Notifier LCM-320 is a Loop Control Module designed to add additional Signaling Line Circuits (SLCs) to NOTIFIER ONYX® Series fire alarm control panels. It provides addressable loop expansion capability for NFS-3030, NFS2-3030, and compatible systems, supporting long-distance SLC communication and improved network flexibility. The module is used in commercial fire alarm installations requiring additional device capacity within a compact control panel configuration.\u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"16\" data-end=\"389\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCM-320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable SLC Loop Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eONYX® Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFS-3030, NFS2-3030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Expander\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEM-320 Loop Expander Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal, 27.6 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 additional Signaling Line Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12,500 ft (3,810 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted-pair, unshielded or shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Wire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 AWG to 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass B Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms maximum per branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass A\/Style 6 \u0026amp; 7 Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms maximum per loop length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum SLC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised addressable SLC communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93% ±2% RH non-condensing at 90°F (32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, FM Approved, CSFM, FDNY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial addressable fire alarm expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.50 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"391\" data-end=\"411\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e LCM-320\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"520\" data-end=\"1152\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe LCM-320 is part of the NOTIFIER ONYX® Series loop control module family, developed to expand intelligent fire alarm control panels with additional SLC channels. The module provides plug-in installation, built-in degraded mode operation, and compatibility with LEM-320 loop expander modules for scalable system growth. It supports Class B (Style 4) SLC wiring with extended loop distances up to 12,500 feet using appropriate twisted-pair wiring. The LCM-320 is designed for use with NFS-3030, NFS2-3030 fire alarm control panels and integrates with NOTIFIER addressable devices for advanced detection and monitoring applications.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1154\" data-end=\"1169\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1171\" data-end=\"2442\"\u003e\n\u003cli data-start=\"1171\" data-end=\"1284\"\u003eSLC Loop Expansion: Adds additional Signaling Line Circuits to NOTIFIER ONYX® Series fire alarm control panels.\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1405\"\u003eONYX® Series Compatibility: Designed for NFS-3030 and NFS2-3030 systems with support for expanded loop configurations.\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1518\"\u003eLong Distance Communication: Supports SLC wiring distances up to 12,500 ft (3,810 m) on Class B Style 4 loops.\u003c\/li\u003e\n\u003cli data-start=\"1519\" data-end=\"1615\"\u003eLEM-320 Compatibility: Allows connection of Loop Expander Modules for additional SLC capacity.\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1735\"\u003ePlug-In Installation: Provides simple installation through direct module insertion into compatible fire alarm panels.\u003c\/li\u003e\n\u003cli data-start=\"1736\" data-end=\"1852\"\u003eDegraded Mode Operation: Maintains improved system survivability during certain communication or fault conditions.\u003c\/li\u003e\n\u003cli data-start=\"1853\" data-end=\"1951\"\u003eMultiple Loop Support: Enables multiple addressable loops within a compact fire alarm enclosure.\u003c\/li\u003e\n\u003cli data-start=\"1952\" data-end=\"2062\"\u003eSupervised SLC Operation: Provides monitored, power-limited communication for connected intelligent devices.\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2161\"\u003eFlexible Wiring Support: Operates with 12 AWG through 18 AWG twisted-pair wiring configurations.\u003c\/li\u003e\n\u003cli data-start=\"2162\" data-end=\"2259\"\u003eHigh Device Capacity: Expands system capability for larger addressable fire detection networks.\u003c\/li\u003e\n\u003cli data-start=\"2260\" data-end=\"2350\"\u003eCompact Module Design: Optimizes panel space while adding additional loop functionality.\u003c\/li\u003e\n\u003cli data-start=\"2351\" data-end=\"2442\"\u003eAgency Approved Design: Listed for UL, ULC, FM, CSFM, FDNY, and other regional approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2444\" data-end=\"2591\"\u003eThe LCM-320 delivers the reliability and precision required for addressable fire alarm loop expansion and intelligent detection system integration.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52130662023466,"sku":"LCM-320","price":595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/LCM-320-1.jpg?v=1785091740","url":"https:\/\/iqelectro.com\/products\/notifier-lcm-320-onyx-addressable-slc-loop-control-module","provider":"IQElectro","version":"1.0","type":"link"}