{"product_id":"notifier-mps-400-6-ampere-main-power-supply-for-afp-300-and-afp-400-fire-alarm-control-panels","title":"Notifier MPS-400 6-Ampere Main Power Supply for AFP-300 and AFP-400 Fire Alarm Control Panels","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Notifier MPS-400 is a 6-ampere main power supply designed for the AFP-300 and AFP-400 intelligent fire alarm control panels. It supplies regulated 24-volt direct current power for system electronics, notification appliances, four-wire smoke detectors, annunciators, and releasing applications while providing four integrated Notification Appliance Circuits and system relay outputs. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPS-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Fire Alarm Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Control Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier AFP-300 and AFP-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Power Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 amperes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 volts alternating current at 3 amperes or 240 volts alternating current at 1.5 amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 hertz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Appliance Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 supervised circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Circuit Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 volts direct current, up to 2.5 amperes per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Circuit Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Resettable Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × 24 volts direct current at 1.25 amperes each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResettable Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 volts direct current at 1.25 amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, Trouble, Supervisory, Security\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForm-C, rated 3 amperes at 30 volts direct current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-rate charger, 2 amperes maximum charging current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.54 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About MPS-400\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe MPS-400 is a Notifier main power supply module developed as part of the AFP-300 and AFP-400 fire alarm control panel architecture. The assembly incorporates four supervised Notification Appliance Circuits, regulated auxiliary power outputs, battery charging circuitry, status indicators, and four Form-C system relays for alarm, trouble, supervisory, and security functions. It accepts field-selectable 120 or 240 volts alternating current and interfaces directly with the control panel processor through dedicated power and signaling connections. Its notification circuits can be configured for Class A or Class B operation and may also be used for releasing applications, allowing the power supply to support alarm notification and fire protection control functions within the same panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e6-Ampere System Capacity: Provides up to 6 amperes of total regulated power, including current consumed by internal system modules. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFour Notification Appliance Circuits: Incorporates four supervised 24-volt direct current circuits rated at up to 2.5 amperes each, subject to the 6-ampere total system limit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eClass A or Class B Operation: Notification circuits support Class A or Class B field wiring for compatible notification appliances. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power Outputs: Provides two non-resettable 24-volt direct current circuits and one resettable 24-volt direct current circuit, each rated at 1.25 amperes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegrated System Relays: Includes Form-C alarm, trouble, supervisory, and security relay contacts rated at 3 amperes at 30 volts direct current. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDual Input Voltage: Supports field-selectable 120 or 240 volts alternating current at 50 or 60 hertz for primary panel power. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBattery Charging Support: Incorporates dual-rate battery charging circuitry and supports standby battery systems required for fire alarm operation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAFP Panel Compatibility: Designed specifically for integration with Notifier AFP-300 and AFP-400 intelligent fire alarm control panels. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MPS-400 delivers the reliability and precision required for regulated fire alarm system power, notification appliance operation, auxiliary device power, and emergency signaling functions.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52604827042090,"sku":"MPS-400","price":1165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_c19ca7df-5454-4d70-b7d8-ed0b8660fea6.webp?v=1789418291","url":"https:\/\/iqelectro.com\/products\/notifier-mps-400-6-ampere-main-power-supply-for-afp-300-and-afp-400-fire-alarm-control-panels","provider":"IQElectro","version":"1.0","type":"link"}