{"product_id":"notifier-nam-232w-twisted-pair-network-adapter-module","title":"Notifier NAM-232W Twisted-Pair Network Adapter Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Notifier NAM-232W is a network adapter module that connects compatible AFP-series fire alarm control panels to the NOTI•FIRE•NET communication network using twisted-pair wiring. It interfaces with the panel through an EIA-232 serial connection and provides network communication for AFP-200, AFP-300, and AFP-400 fire alarm control panels.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNAM-232W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Network Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Adapter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNOTI•FIRE•NET (NFN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Control Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFP-200, AFP-300, AFP-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEIA-232 (RS-232) Serial Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted-Pair Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e312.5 Kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Handling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData regenerated at each network node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolation between network nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIP-switch selectable single-port or dual-port monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Drill Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIP-switch selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer-channel selectable detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 × 10 × 4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About NAM-232W\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe NAM-232W is a Notifier wire-medium Network Adapter Module designed for integrating legacy AFP-series panels into a NOTI•FIRE•NET network. It communicates with the host fire alarm control panel through an EIA-232 (RS-232) serial port and operates over a two-channel twisted-pair network bus. The module transmits network data at 312.5 Kbaud and regenerates data at each network node to maintain communication integrity. Electrical isolation between nodes and selectable monitoring, network drill, and earth fault detection functions support network supervision and diagnostics.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eTwisted-Pair Networking: Connects compatible fire alarm panels to NOTI•FIRE•NET using copper twisted-pair wiring.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAFP Panel Compatibility: Designed for use with AFP-200, AFP-300, and AFP-400 fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eRS-232 Interface: Connects to the host control panel through an EIA-232 serial communication port.\u003c\/li\u003e\n\u003cli\u003eDual-Channel Network Bus: Supports a two-channel twisted-pair network communication architecture.\u003c\/li\u003e\n\u003cli\u003e312.5 Kbaud Transmission: Provides high-speed NFN data communication at 312.5 Kbaud.\u003c\/li\u003e\n\u003cli\u003eData Regeneration: Regenerates network data at each node to maintain signal integrity across the network.\u003c\/li\u003e\n\u003cli\u003eElectrical Isolation: Provides isolation between network nodes to help prevent faults from propagating between panels.\u003c\/li\u003e\n\u003cli\u003eDiagnostic and DIP Controls: Includes diagnostic LEDs and DIP-switch selectable monitoring, network drill, and per-channel earth fault detection options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NAM-232W delivers the reliability and precision required for integrating compatible fire alarm control panels into supervised NOTI•FIRE•NET communication networks.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52563487818026,"sku":"NAM-232W","price":1425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_9d641b10-c1ef-445e-9ef2-0e110f12fbcd.webp?v=1789073893","url":"https:\/\/iqelectro.com\/products\/notifier-nam-232w-twisted-pair-network-adapter-module","provider":"IQElectro","version":"1.0","type":"link"}