{"product_id":"notifier-rp-1002-agent-releasing-control-panel-for-clean-agent-fire-suppression-systems","title":"Notifier RP-1002 Agent Releasing Control Panel for Clean Agent Fire Suppression Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Notifier RP-1002 is a UL-listed agent releasing control panel designed to operate clean agent fire suppression systems. It features dual-zone detection, cross-zone logic, programmable delays, and advanced safety supervision.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 560px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.9219px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 34.9219px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 34.9219px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.4219px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 27.4219px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 27.4219px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNotifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.4219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.4219px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.4219px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eFire Safety\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.2969px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.2969px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.2969px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eRP-1002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.7188px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 23.7188px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 23.7188px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eFire Alarm Control\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003e\u003cspan\u003ePower Input\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e120 VAC, 60 Hz, 1.2 A (optional 230 VAC, 50 Hz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003eInitiating Circuits\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eStyle B (Class B) \/ Style D (Class A)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 32.1875px;\"\u003eNotification Circuits\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 32.1875px;\"\u003eStyle Y\/Z, up to 1.5 A per circuit\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eReleasing Circuits\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eStyle Y, up to 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.5938px;\"\u003eVoltage Output\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.5938px;\"\u003e24 VDC RMS regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eMax Total Output Load\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e2.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003eSupervisory Current\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 31.1875px;\"\u003eDelay Options\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 31.1875px;\"\u003e0 \/ 10 \/ 20 \/ 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 22.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBattery Capacity\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 22.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e6.5 AH to 15 AH, up to 90 hours standby\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eFour-Wire Detector Power\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e200 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eNon-Resettable Aux Power\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e24 VDC regulated, 200 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eCabinet Dimensions (HxWxD)\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e16.0\" x 14.5\" x 5.375\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eStandards Compliance\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eNFPA 12, 12A, 72, 2001; UL, ULC, FM, MEA, CSFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eRelay Contact Rating\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e2 A @ 30 VDC; 0.5 A @ 30 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eEnd-of-Line Resistor\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e4.7 kΩ, ½ W (P\/N 71252)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5625px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.5625px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.5625px;\"\u003e\u003cspan\u003e15 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eRP-1002\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe RP-1002 is a flexible and robust control unit engineered to handle gaseous fire suppression agents in compliance with multiple NFPA standards, including NFPA 12 for CO₂, NFPA 12A for Halon 1301, and NFPA 2001 for clean agent systems. This panel supports both Style B and D configurations for initiating and abort circuits, and Style Y\/Z for notification and releasing outputs. Its dual-hazard capability allows operators to control two separate suppression areas, or alternatively, configure one of the releasing circuits as a supervisory input. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-Hazard Releasing Support: Can control two separate suppression zones or one zone with supervisory input.\u003c\/li\u003e\n\u003cli\u003eMulti-Standard Compliance: Meets NFPA 72, NFPA 12, NFPA 12A, and NFPA 2001 standards for agent suppression.\u003c\/li\u003e\n\u003cli\u003ePower-Limited Circuitry: All input and output circuits (except municipal box output) are current-limited for safety.\u003c\/li\u003e\n\u003cli\u003eDelay Timer Configuration: Field-selectable activation delay settings of 0, 10, 20, or 30 seconds.\u003c\/li\u003e\n\u003cli\u003eCross-Zone Activation Option: Provides enhanced protection by requiring confirmation from two initiating devices.\u003c\/li\u003e\n\u003cli\u003eAbort and Manual Release Inputs: Dedicated Style B\/D circuits for local abort and manual discharge control.\u003c\/li\u003e\n\u003cli\u003eMultiple Notification Outputs: Two Style Y\/Z notification appliance circuits for alarm and release tones.\u003c\/li\u003e\n\u003cli\u003eModular Expansion Capability: Supports optional modules like 4XZM (relay), 4XTM (transmitter), 4XMM (meters), RZA-4X (remote annunciator), and 4XLM (LED interface).\u003c\/li\u003e\n\u003cli\u003eAudible and Visual Feedback: Distinct tones and indicators for one zone alarm, two zones alarm, and system release.\u003c\/li\u003e\n\u003cli\u003eWatchdog Timer and Event Recall: Supervises processor operation and stores last trouble event for diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RP-1002 offers code-compliant agent release functionality with modular expansion, making it ideal for high-risk environments requiring advanced fire suppression control.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":50411643699498,"sku":"RP-1002","price":1392.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/honeywell-2-loop-fire-alarm-control-panel-500x500.jpg?v=1752823729","url":"https:\/\/iqelectro.com\/products\/notifier-rp-1002-agent-releasing-control-panel-for-clean-agent-fire-suppression-systems","provider":"IQElectro","version":"1.0","type":"link"}