{"product_id":"notifier-rp-2001e-fire-alarm-control-panel-quick-delivery","title":"Notifier RP-2001E Six-Zone Deluge-Preaction Fire Alarm Control Panel with FLPS-7 Power Supply","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier RP-2001E Deluge-Preaction Control Panel is a six-zone, microprocessor-based fire alarm control unit designed for single and dual-hazard water-based suppression systems. Equipped with an FLPS-7 power supply rated at 240 VAC, 50 Hz, 2.085 amps, this panel provides precise detection and control for deluge and preaction fire suppression applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eRP-2001E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eDeluge-Preaction Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSix-zone fire alarm and releasing control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eSupported Hazards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSingle or dual hazard (deluge\/preaction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eFLPS-7 integrated power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e240 VAC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e2.085 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eDetection Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSix supervised zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eNotification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eTwo supervised outputs (NACs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eProgrammable relays for alarm and trouble functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eNotifier-compatible modules and accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eOpen, short, and ground fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eUp to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCabinet Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSteel enclosure, red powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eUL Listed; NFPA 72 and releasing service compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eApprox. 26\" H × 18\" W × 5.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e29 lb (13.15 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About RP-2001E\u003c\/h4\u003e\n\u003cp\u003eThe RP-2001E is a Notifier six-zone control panel engineered to manage deluge and preaction sprinkler systems in industrial, commercial, and special hazard facilities. It supports both single and dual-hazard configurations, offering flexibility for complex fire protection layouts. The integrated FLPS-7 power supply provides stable 24 VDC system power and supervision for connected detection and release circuits. Designed for compatibility with Notifier detectors, modules, and notification appliances, the RP-2001E meets UL and NFPA requirements for releasing service and fire suppression control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix Detection Zones: Supports multiple supervised input circuits for system flexibility.\u003c\/li\u003e\n\u003cli\u003eDual-Hazard Capability: Configurable for single or dual-hazard deluge or preaction systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated Power Supply: Includes FLPS-7 module rated at 240 VAC, 50 Hz, 2.085 A.\u003c\/li\u003e\n\u003cli\u003eReleasing Service Approved: Designed and listed for use with deluge and preaction suppression applications.\u003c\/li\u003e\n\u003cli\u003eNotifier System Integration: Compatible with a wide range of Notifier detectors and notification devices.\u003c\/li\u003e\n\u003cli\u003eSupervised Circuits: Ensures fault detection for open, short, and ground conditions.\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Interface: LED indicators and zone controls simplify monitoring and operation.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliant: Meets requirements for fire alarm and releasing service panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RP-2001E delivers the reliability and precision required for deluge and preaction fire suppression control in demanding industrial and commercial applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":50667063771434,"sku":"RP-2001E","price":1112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/RP-2001E.webp?v=1759910136","url":"https:\/\/iqelectro.com\/products\/notifier-rp-2001e-fire-alarm-control-panel-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}