{"product_id":"notifier-rp-2002e-six-zone-fire-alarm-control-panel-for-agent-releasing","title":"Notifier RP-2002E Six-Zone Fire Alarm Control Panel for Agent Releasing","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Notifier RP-2002E is a six-zone fire alarm control panel designed for single- and dual-hazard agent releasing applications. It provides fire detection, alarm signaling, and releasing control for commercial, industrial, and institutional life-safety systems.\u003c\/p\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 81.0141%; height: 274.313px;\" height=\"352\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eFire Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eRP-2002E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eReleasing Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eHoneywell International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eZone Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eSix Zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eSingle- and Dual-Hazard Agent Releasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eConventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eFire Detection, Signaling, and Agent Releasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eListings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003eCSFM, FM, MEA, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003e8.50 × 22.50 × 20.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.056%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6481%; height: 19.5938px;\"\u003e16.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eRP-2002E\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe RP-2002E is part of Notifier’s releasing fire alarm control panel family for agent-based fire suppression systems. Its six-zone architecture supports conventional detection and releasing configurations for applications requiring dedicated hazard protection. The panel is designed to coordinate detection, notification, and agent release functions within a centralized control unit. It is approved for use under multiple fire protection standards and listings, including UL, FM, CSFM, and MEA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSix-Zone Configuration: Provides six conventional zones for fire detection and releasing applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAgent Releasing Control: Designed for single- and dual-hazard fire suppression systems using compatible releasing agents.\u003c\/li\u003e\n\u003cli\u003eFire Detection: Supports centralized monitoring of connected conventional initiating devices.\u003c\/li\u003e\n\u003cli\u003eAlarm Signaling: Coordinates fire alarm notification functions as part of the protected system.\u003c\/li\u003e\n\u003cli\u003eCommercial Applications: Suitable for commercial, industrial, and institutional fire protection installations.\u003c\/li\u003e\n\u003cli\u003eMultiple Approvals: Listed with CSFM, FM, MEA, and UL approvals.\u003c\/li\u003e\n\u003cli\u003eCentralized Control: Integrates detection, signaling, and agent releasing functions within one control panel.\u003c\/li\u003e\n\u003cli\u003ePanel Construction: Designed as a dedicated fire alarm control unit for fixed suppression applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RP-2002E delivers the reliability and precision required for agent-releasing fire alarm control systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52562325602602,"sku":"RP-2002E","price":3999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/RP-2002E-Main.jpg?v=1789061670","url":"https:\/\/iqelectro.com\/products\/notifier-rp-2002e-six-zone-fire-alarm-control-panel-for-agent-releasing","provider":"IQElectro","version":"1.0","type":"link"}