{"product_id":"notifier-scs-8l-smoke-control-lamp-driver-module-eight-switch-groups","title":"Notifier SCS-8L Smoke Control Lamp Driver Module Eight Switch Groups","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Notifier SCS-8L is a Smoke Control Lamp Driver Master Module designed to provide visual status indication in compatible smoke control systems. It supports eight independent switch groups and provides connections for indicator lamps or LEDs associated with fans, dampers, and other smoke control equipment. The module is intended for installation in a compatible UL-listed custom graphic annunciator panel.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCS-8L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke Control Lamp Driver Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCS Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Switch Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Group Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-position switch connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp\/LED Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree lamp or LED connections per switch group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFans, dampers, or groups of fans and dampers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFirefighter Smoke Control Station and HVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible Notifier fire alarm control panels and network annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL-listed custom graphic annunciator backbox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with SCE-8L expander module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot specified for the lamp-driver module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent; refer to the applicable installation documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.25 × 5.1 × 4.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally open, 2 A at 30 VDC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrouble Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed, 2 A at 30 VDC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 seconds for alarm and trouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMore than 5 seconds with power-down reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SCS-8L\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe SCS-8L belongs to the Notifier SCS Series of smoke control station components manufactured by Honeywell. It is the lamp-driver version of the SCS-8 master module and is designed for use with compatible Notifier fire alarm control panels and network annunciators. The module provides connections for three-position switch controls and three indicator lamps or LEDs for each of its eight switch groups. It must be installed in a UL-listed graphic annunciator backbox and can be expanded using a compatible SCE-8L module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eLamp Driver Module: Provides dedicated outputs for visual status indicators in compatible smoke control systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEight Switch Groups: Supports control and indication for up to eight fans, dampers, or equipment groups.\u003c\/li\u003e\n\u003cli\u003eIndicator Connections: Includes connections for three lamps or LEDs associated with each switch group.\u003c\/li\u003e\n\u003cli\u003eThree-Position Switch Support: Accommodates ON\/AUTO\/OFF-style control switches for smoke control equipment.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for integration with compatible Notifier fire alarm control panels and annunciators.\u003c\/li\u003e\n\u003cli\u003eGraphic Annunciator Installation: Intended for use with compatible UL-listed custom graphic annunciator panels.\u003c\/li\u003e\n\u003cli\u003eSystem Expansion: Supports expansion through a compatible SCE-8L module.\u003c\/li\u003e\n\u003cli\u003eSmoke Control Applications: Suitable for firefighter smoke control and HVAC equipment monitoring applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SCS-8L delivers the reliability and precision required for visual status indication and equipment monitoring in compatible smoke control and fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52589050593578,"sku":"SCS-8L","price":687.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_39f9c146-983b-4d80-867d-98262a44816e.webp?v=1789237726","url":"https:\/\/iqelectro.com\/products\/notifier-scs-8l-smoke-control-lamp-driver-module-eight-switch-groups","provider":"IQElectro","version":"1.0","type":"link"}