{"product_id":"notifier-vesda-hli-gw-vesdanet-high-level-interface-network-gateway","title":"NOTIFIER VESDA-HLI-GW VESDAnet High-Level Interface Network Gateway","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe NOTIFIER VESDA-HLI-GW is a VESDAnet High-Level Interface Gateway that provides a communication link between the NOTI-FIRE-NET network and compatible VESDA aspirating smoke detectors. It translates VESDAnet information for NFN communication, enabling detector event monitoring, annunciation, status reporting, and supported control functions through compatible NOTIFIER network equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 87.6812%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eNOTIFIER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eVESDA-HLI-GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eNetwork Interface Gateways\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eVESDAnet High-Level Interface Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eNOTI-FIRE-NET to VESDAnet Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eStandard or High-Speed NOTI-FIRE-NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eVESDA Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eVHX-1420-HFS High Level Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eHLI Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eMaximum Detector Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eUp to 100 VESDA Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eDisplayed Device Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eAspiration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eCompatible Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eNCA-2, LCD-160, ONYXWorks, NFS2-3030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eSupported Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eEvent Monitoring, Read Status, Detector Control, Zone Mapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eCompatible VESDA Families\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eVLP, VLF, VLS, VLC, VLI, VEP, VEU, VEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eCommunication Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eVHX-1420-HFS Communication Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8502%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%;\"\u003eApprox. 2 lb (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e VESDA-HLI-GW\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe VESDA-HLI-GW is a NOTIFIER network gateway designed to integrate Xtralis VESDAnet detection equipment with standard or high-speed NOTI-FIRE-NET systems. It communicates with the VHX-1420-HFS High Level Interface through an RS-232 connection using Modbus protocol and supervises this communication path for faults. The gateway can monitor up to 100 VESDA detectors and presents connected units as “Aspiration” device types on compatible network display nodes. It supports integration with equipment such as NCA-2, LCD-160, ONYXWorks, and NFS2-3030 systems configured for applicable network display functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eNFN-to-VESDAnet Integration: Provides a communications bridge between NOTI-FIRE-NET and the VESDAnet detection network. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e100-Detector Capacity: Supports monitoring and event notification for up to 100 compatible VESDA detectors. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus Communication: Communicates with the VHX-1420-HFS interface using Modbus protocol through an RS-232 connection.\u003c\/li\u003e\n\u003cli\u003eSupervised HLI Connection: Monitors communication with the VHX-1420-HFS and reports applicable communication faults.\u003c\/li\u003e\n\u003cli\u003eAspiration Device Display: Connected VESDA detectors appear as “Aspiration” devices on compatible NFN display nodes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEvent Monitoring: Supports annunciation of pre-alarm, fire alarm, point-disable, detector fault, airflow, filter, and communication conditions.\u003c\/li\u003e\n\u003cli\u003eDetector Control: Enables supported VESDAnet detector control functions from compatible NCA-2, ONYXWorks, and NFS2-3030 interfaces. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eZone Mapping: Provides zone-mapping capability for integration of VESDA detector events into the NOTIFIER network architecture. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe VESDA-HLI-GW delivers the reliability and precision required for integrating aspirating smoke detection with networked fire alarm monitoring and control systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":52256131252522,"sku":"VESDA-HLI-GW","price":3999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_bd060efc-b87e-4102-a536-d90aee888c34.webp?v=1786612272","url":"https:\/\/iqelectro.com\/products\/notifier-vesda-hli-gw-vesdanet-high-level-interface-network-gateway","provider":"IQElectro","version":"1.0","type":"link"}