{"product_id":"p2150su-396-akrx24-ep2-belimo-1-5-inch-pressure-independent-control-valve-with-24v-actuator","title":"P2150SU-396+AKRX24-EP2 | Belimo 1.5 Inch Pressure Independent Control Valve With 24V Actuator","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"132\" data-end=\"401\"\u003eThe Belimo P2150SU-396+AKRX24-EP2 is a 1.5 inch pressure independent control valve assembly with an integrated 24 V modulating spring return actuator. It provides precise flow control up to 39.6 GPM with integrated ultrasonic flow measurement for hydronic HVAC systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eBelimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eControl Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eP2150SU-396+AKRX24-EP2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003ePressure Independent Control Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eValve Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e1.5 in (DN 40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eNominal Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e39.6 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eFlow Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eEqual percentage or linear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eMinimum Controllable Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e1% of V’nom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eClose-Off Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e200 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eBody Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e360 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eDifferential Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e5…50 psi or 1…50 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eFluid Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eChilled or hot water, up to 60% glycol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eFluid Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e14…250°F (-10…120°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eControl Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e2…10 V (4…20 mA with resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003ePosition Feedback\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e2…10 V, VDC variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eFlow Measurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eFlow Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eUltrasonic with glycol and temperature compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eAC\/DC 24 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003ePower Consumption (Running)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eRunning Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e90 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eFail-Safe Running Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e\u0026lt;35 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003eIP54 \/ NEMA 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e-22…122°F (-30…50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6619%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9745%;\"\u003e8.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eP2150SU-396+AKRX24-EP2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe P2150SU-396+AKRX24-EP2 is part of Belimo’s pressure independent control valve portfolio designed to deliver stable flow control regardless of system pressure fluctuations. The valve integrates ultrasonic flow measurement with temperature and glycol compensation, enabling accurate real-time flow regulation and monitoring. Its factory-mounted AKRX24-EP2 spring return actuator operates on AC\/DC 24 V and supports modulating control with configurable feedback signals. Designed for maintenance-free service, the assembly ensures consistent hydronic performance and simplified system balancing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Independent Flow Control: Maintains constant flow rates despite varying system differential pressures.\u003c\/li\u003e\n\u003cli\u003eIntegrated Ultrasonic Flow Measurement: Provides accurate flow sensing with ±2% accuracy and temperature compensation.\u003c\/li\u003e\n\u003cli\u003eModulating Spring Return Actuator: Ensures precise control with automatic fail-safe positioning during power loss.\u003c\/li\u003e\n\u003cli\u003eFlexible Control Signal Support: Accepts 2…10 V control with optional 4…20 mA input via external resistor.\u003c\/li\u003e\n\u003cli\u003eHigh Control Precision: Achieves ±5% control accuracy with repeatable flow performance.\u003c\/li\u003e\n\u003cli\u003eWide Fluid Compatibility: Designed for chilled and hot water systems with glycol concentrations up to 60%.\u003c\/li\u003e\n\u003cli\u003eCompact Integrated Assembly: Factory-assembled valve and actuator simplify installation and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe P2150SU-396+AKRX24-EP2 delivers the reliability and precision required for accurate pressure independent flow control in modern HVAC hydronic systems.\u003c\/p\u003e","brand":"Belimo","offers":[{"title":"Default Title","offer_id":51042796568874,"sku":"P2150SU-396+AKRX24-EP2","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_1d282f55-801c-4b7f-add8-445538b6e582.webp?v=1768071008","url":"https:\/\/iqelectro.com\/products\/p2150su-396-akrx24-ep2-belimo-1-5-inch-pressure-independent-control-valve-with-24v-actuator","provider":"IQElectro","version":"1.0","type":"link"}