{"product_id":"parker-73218bn4unlvn0c111c2-2-way-normally-closed-1-2-inch-npt-24vdc-pilot-operated-solenoid-valve","title":"Parker 73218BN4UNLVN0C111C2 2-Way Normally Closed 1\/2-Inch NPT 24VDC Pilot-Operated Solenoid Valve","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Parker 73218BN4UNLVN0C111C2 is a 2-way, normally closed solenoid valve designed for automatic control of fluid flow through a 1\/2-inch NPT connection. Its internally pilot-operated design uses a 24 VDC solenoid, brass valve body, and NBR sealing components for controlled on\/off operation in compatible fluid systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 87.6812%; height: 441.064px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eValves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e73218BN4UNLVN0C111C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eSolenoid Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eValve Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e2-Way Solenoid Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eNormally Closed (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 10px;\"\u003e\u003cstrong\u003eActuation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 10px;\"\u003ePilot Operated, Internal Pilot Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eFemale NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eNBR \/ Buna-N \/ Nitrile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eCoil Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eClass F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eCoil Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e1\/2 in NPT Conduit with 18 in Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003eNEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eOrifice Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e5\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlow Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e4 Cv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003ePressure Differential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e5–175 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Fluid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e185°F (85°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5304%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2205%; height: 19.5938px;\"\u003e2.07 lb (0.94 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e73218BN4UNLVN0C111C2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 73218BN4UNLVN0C111C2 is a Parker Skinner pilot-operated solenoid valve configured with an internal pilot supply and normally closed flow pattern. The valve incorporates a brass inline body, female NPT process connections, and NBR elastomer seals. Its electrical operator uses a 10 W Class F coil rated for 24 VDC, with a 1\/2-inch NPT conduit connection and 18-inch leads. The NEMA 4X coil construction supports automatic valve actuation in industrial fluid-control installations where a pressure differential is available for pilot operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e2-Way Configuration: Provides controlled inlet-to-outlet flow through a two-port valve arrangement.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNormally Closed Operation: Maintains the valve in the closed position when the solenoid is de-energized.\u003c\/li\u003e\n\u003cli\u003eInternal Pilot Actuation: Uses process pressure and an internal pilot supply to operate the main valve mechanism.\u003c\/li\u003e\n\u003cli\u003e1\/2-Inch NPT Ports: Female threaded process connections provide compatibility with standard 1\/2-inch NPT piping.\u003c\/li\u003e\n\u003cli\u003e24 VDC Solenoid: Operates from a 24 VDC electrical supply with a 10 W Class F coil.\u003c\/li\u003e\n\u003cli\u003eBrass Body: Inline brass construction provides the primary pressure-containing valve structure.\u003c\/li\u003e\n\u003cli\u003eNBR Seals: Buna-N\/Nitrile elastomers provide sealing for compatible fluids and operating conditions.\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Coil Construction: Solenoid operator is configured with a 1\/2-inch NPT conduit connection, Class F construction, and 18-inch leads. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 73218BN4UNLVN0C111C2 delivers the reliability and precision required for automated on\/off fluid control in compatible industrial piping systems.\u003c\/p\u003e","brand":"Parker","offers":[{"title":"Default Title","offer_id":52257247789354,"sku":"73218BN4UNLVN0C111C2","price":397.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/parker-73218bn4unlvn0c111c2.jpg?v=1786639835","url":"https:\/\/iqelectro.com\/products\/parker-73218bn4unlvn0c111c2-2-way-normally-closed-1-2-inch-npt-24vdc-pilot-operated-solenoid-valve","provider":"IQElectro","version":"1.0","type":"link"}