{"product_id":"pepperl-fuchs-kfd2-cd-ex1-32-1-channel-ex-current-driver-4-20ma","title":"Pepperl+Fuchs KFD2-CD-EX1.32 1-Channel Ex Current Driver 4-20mA","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-path-to-node=\"31,0,0\"\u003eThe Pepperl+Fuchs KFD2-CD-EX1.32 is a single-channel current driver designed to safely power proportional valves and I\/P converters in hazardous areas. Operating on a 24V DC supply, it provides a strictly controlled analog output signal up to 20 mA. It is engineered to isolate electrical energy and maintain strict intrinsic safety during continuous fluid and gas regulation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"84\" style=\"width: 87.7457%; height: 281px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,1,0,0\"\u003e\u003cb data-path-to-node=\"94,1,0,0\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,1,1,0\"\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,2,0,0\"\u003e\u003cb data-path-to-node=\"94,2,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,2,1,0\"\u003ePepperl+Fuchs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,3,0,0\"\u003e\u003cb data-path-to-node=\"94,3,0,0\" data-index-in-node=\"0\"\u003eCategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,3,1,0\"\u003eIndustrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,4,0,0\"\u003e\u003cb data-path-to-node=\"94,4,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,4,1,0\"\u003eKFD2-CD-EX1.32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,5,0,0\"\u003e\u003cb data-path-to-node=\"94,5,0,0\" data-index-in-node=\"0\"\u003eSubcategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,5,1,0\"\u003eCurrent Drivers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,6,0,0\"\u003e\u003cb data-path-to-node=\"94,6,0,0\" data-index-in-node=\"0\"\u003eChannel Count\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,6,1,0\"\u003e1 Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,7,0,0\"\u003e\u003cb data-path-to-node=\"94,7,0,0\" data-index-in-node=\"0\"\u003eSupply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,7,1,0\"\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,8,0,0\"\u003e\u003cb data-path-to-node=\"94,8,0,0\" data-index-in-node=\"0\"\u003eInput Signal\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,8,1,0\"\u003e4-20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,9,0,0\"\u003e\u003cb data-path-to-node=\"94,9,0,0\" data-index-in-node=\"0\"\u003eOutput Signal\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,9,1,0\"\u003e4-20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,10,0,0\"\u003e\u003cb data-path-to-node=\"94,10,0,0\" data-index-in-node=\"0\"\u003eSafety Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,10,1,0\"\u003eIntrinsically Safe (Ex)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1478%;\"\u003e\u003cspan data-path-to-node=\"94,11,0,0\"\u003e\u003cb data-path-to-node=\"94,11,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.3196%;\"\u003e\u003cspan data-path-to-node=\"94,11,1,0\"\u003e0.35 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eKFD2-CD-EX1.32\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-path-to-node=\"81,1,0\"\u003eThe KFD2-CD-EX1.32 is a highly dependable galvanic isolator built to bridge safe-zone analog controllers with explosive-area actuators. It utilizes precise internal circuitry to ensure the control signal driving the field device perfectly matches the input from the PLC. Designed for integration into heavy chemical and petrochemical control panels, it safeguards critical equipment against dangerous electrical surges and ground loops. It features open-circuit detection to alert maintenance systems instantly if the field connection is compromised.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"92,0,0\"\u003eIntrinsic Safety Compliance: Galvanically isolates output channels to prevent ignition in highly explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"92,1,0\"\u003ePrecise Signal Driving: Translates safe-area analog commands perfectly to control hazardous-area proportional valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"92,2,0\"\u003eLine Fault Detection: Monitors output circuits actively to identify and report dangerous open connections immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"92,3,0\"\u003e24V DC Operation: Designed to integrate easily into standard low-voltage industrial control and DCS cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"92,4,0\"\u003eHigh Output Capacity: Delivers stable current up to 20 mA to drive heavy-duty I\/P converters effortlessly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"92,5,0\"\u003eCompact Footprint: Features a streamlined DIN-rail mountable design to conserve valuable control panel space. \u003cbr\u003eThe KFD2-CD-EX1.32 delivers the reliability and precision required for safe analog actuation and hazardous area fluid control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":53045987967274,"sku":"KFD2-CD-EX1.32","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_cccb6c6f-32d2-4cae-b7ea-77897d602edb.jpg?v=1792524652","url":"https:\/\/iqelectro.com\/products\/pepperl-fuchs-kfd2-cd-ex1-32-1-channel-ex-current-driver-4-20ma","provider":"IQElectro","version":"1.0","type":"link"}