{"product_id":"pepperl-fuchs-kfu8-gut-ex1-d-temperature-converter-with-trip-values","title":"Pepperl+Fuchs KFU8-GUT-Ex1.D Temperature Converter with Trip Values","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003ePepperl+Fuchs \u003c\/span\u003e\u003cspan\u003eKFU8-GUT-Ex1.D \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003etemperature \u003c\/span\u003e\u003cspan\u003econverter \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003etrip-value \u003c\/span\u003e\u003cspan\u003emonitoring \u003c\/span\u003e\u003cspan\u003edesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003eprocess \u003c\/span\u003e\u003cspan\u003eautomation \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eintrinsically \u003c\/span\u003e\u003cspan\u003esafe \u003c\/span\u003e\u003cspan\u003emeasurement \u003c\/span\u003e\u003cspan\u003eapplications. \u003c\/span\u003e\u003cspan\u003eIt \u003c\/span\u003e\u003cspan\u003eaccepts \u003c\/span\u003e\u003cspan\u003esignals \u003c\/span\u003e\u003cspan\u003efrom \u003c\/span\u003e\u003cspan\u003ethermocouples, \u003c\/span\u003e\u003cspan\u003eresistance \u003c\/span\u003e\u003cspan\u003etemperature \u003c\/span\u003e\u003cspan\u003edetectors \u003c\/span\u003e\u003cspan\u003e(RTDs), \u003c\/span\u003e\u003cspan\u003epotentiometers, \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003evoltage \u003c\/span\u003e\u003cspan\u003esources \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003econverts \u003c\/span\u003e\u003cspan\u003ethem \u003c\/span\u003e\u003cspan\u003einto \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003eproportional \u003c\/span\u003e\u003cspan\u003e0\/4–20 \u003c\/span\u003e\u003cspan\u003emA \u003c\/span\u003e\u003cspan\u003eoutput, \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003etwo \u003c\/span\u003e\u003cspan\u003erelay \u003c\/span\u003e\u003cspan\u003eoutputs \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003elimit \u003c\/span\u003e\u003cspan\u003emonitoring. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ANObbW_Badge lKEGNW_Badge\" data-color=\"secondary\" data-size=\"sm\" data-pill=\"\" data-variant=\"soft\" data-d-component=\"badge\" data-d-hoverable=\"\" data-d-weight=\"normal\"\u003e\n\u003cdiv class=\"oIb9lq_Box\" data-d-auto-spacing=\"\" data-d-component=\"row\" data-d-direction=\"row\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"oIb9lq_Box\" data-d-auto-spacing=\"\" data-d-component=\"row\" data-d-direction=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePepperl+Fuchs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKFU8-GUT-Ex1.D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Signal Converters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Converter with Trip Values\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eK-System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInput Types\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermocouple, RTD, Potentiometer, Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRTD Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt500, Pt1000, Ni100, Ni1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eThermocouple Types\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB, E, J, K, L, N, R, S, T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnalog Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0\/4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRelay Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–90 V DC \/ 48–253 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFunctional Safety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−4°F to 140°F (−20°C to 60°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.6 × 4.7 × 4.5 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.66 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan\u003eInformation \u003c\/span\u003e\u003cspan\u003eAbout KFU8-GUT-Ex1.D\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe KFU8-GUT-Ex1.D belongs to the Pepperl+Fuchs K-System range of isolated signal conditioning devices. Its universal input supports multiple temperature and voltage measurement methods, including redundant thermocouple configurations, while built-in sensor-break and short-circuit monitoring help identify measurement faults. The module provides galvanic isolation and supports intrinsically safe signal transmission for compatible hazardous-area instrumentation. Configuration is available through PACTware software or the front keypad, and the device supports functional safety up to SIL 2 under applicable standards. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e \u003cmeta charset=\"UTF-8\"\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eUniversal Measurement Input: Accepts thermocouple, RTD, potentiometer, and voltage signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAnalog Output: Provides a proportional 0\/4–20 mA output signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eRelay Outputs: Includes two relay contacts for configurable trip-value monitoring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntrinsic Safety: Supports compatible intrinsically safe measurement circuits in hazardous-area applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSensor Fault Detection: Monitors for sensor breakage and short circuits where supported.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eConfiguration Options: Configurable using PACTware software or the integrated keypad.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFunctional Safety: Rated up to SIL 2 under applicable safety standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eDIN-Rail Mounting: Installs on a standard 35 mm DIN rail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe KFU8-GUT-Ex1.D delivers the reliability and precision required for temperature measurement, process signal conversion, and limit monitoring in industrial automation systems. \u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"2127\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"703\" data-end=\"1384\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"730\" data-end=\"1339\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1027\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1720\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"964\" data-end=\"1745\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"895\" data-end=\"1639\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"999\" data-end=\"1761\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"937\" data-end=\"1684\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"865\" data-end=\"1570\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"959\" data-end=\"1674\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"968\" data-end=\"1715\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1019\" data-end=\"1782\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"873\" data-end=\"1681\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1089\" data-end=\"1853\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1030\" data-end=\"1752\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"889\" data-end=\"1649\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"968\" data-end=\"1691\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"885\" data-end=\"1615\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"878\" data-end=\"1601\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003col start=\"3\"\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003col start=\"3\"\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":52989806575914,"sku":"KFU8-GUT-Ex1.D","price":1185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/d3f33750ee8849939a3b741555ff28a5.jpg?v=1792249010","url":"https:\/\/iqelectro.com\/products\/pepperl-fuchs-kfu8-gut-ex1-d-temperature-converter-with-trip-values","provider":"IQElectro","version":"1.0","type":"link"}