{"product_id":"pepperl-fuchs-vas-2a8l-ke4-8se-as-interface-safety-monitor-controller","title":"Pepperl+Fuchs VAS-2A8L-KE4-8SE AS-Interface Safety Monitor Controller","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Pepperl+Fuchs VAS-2A8L-KE4-8SE is an AS-Interface safety monitor designed to supervise safety-related signals and control safety functions in industrial automation systems. It features eight decentralized output circuits, integrated safe inputs and outputs, and an 18–31.6 V supply range for safety system integration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 824.485px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eNew\/Never \u003c\/span\u003e\u003cspan\u003eUsed \u003c\/span\u003e\u003cspan\u003eSurplus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePepperl+Fuchs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eSystems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eVAS-2A8L-KE4-8SE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eControllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eClassification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eAS-Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003e18–31.6 \u003c\/span\u003e\u003cspan\u003eV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSafe Inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSafe Outputs (OSSDs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5556px;\"\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLogical Safe Output Groups\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eSIMON+\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eMuting, \u003c\/span\u003e\u003cspan\u003etiming, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003elogic \u003c\/span\u003e\u003cspan\u003efunctions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eDIN \u003c\/span\u003e\u003cspan\u003erail\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003eUp \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eSIL \u003c\/span\u003e\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003ePerformance \u003c\/span\u003e\u003cspan\u003eLevel \u003c\/span\u003e\u003cspan\u003ee, \u003c\/span\u003e\u003cspan\u003esubject \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003esystem \u003c\/span\u003e\u003cspan\u003edesign\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eAlternate Manufacturer Part Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003e261493\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.5221%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2342%;\"\u003e\n\u003cp\u003e\u003cspan\u003e1.00 \u003c\/span\u003e\u003cspan\u003elb\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eVAS-2A8L-KE4-8SE\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe VAS-2A8L-KE4-8SE is a compact safety controller for AS-Interface networks, designed for applications requiring safety monitoring and configurable logic functions. It provides four integrated safe inputs, two safe outputs (OSSDs), and eight logical safe output groups that can be switched according to the configured safety logic. The unit supports parameterization of muting, timing, and logic functions through SIMON+ software and includes an expansion port for additional functionality. It is designed for DIN-rail mounting and has an IP20 degree of protection for installation inside suitable electrical enclosures.\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAS-Interface \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003emonitoring: \u003c\/span\u003e\u003cspan\u003eSupervises \u003c\/span\u003e\u003cspan\u003esafety-related \u003c\/span\u003e\u003cspan\u003esignals \u003c\/span\u003e\u003cspan\u003ewithin \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eAS-Interface \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eEight \u003c\/span\u003e\u003cspan\u003edecentralized \u003c\/span\u003e\u003cspan\u003eoutput \u003c\/span\u003e\u003cspan\u003ecircuits: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003emultiple \u003c\/span\u003e\u003cspan\u003esafety-related \u003c\/span\u003e\u003cspan\u003eoutput \u003c\/span\u003e\u003cspan\u003ecircuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated \u003c\/span\u003e\u003cspan\u003esafe \u003c\/span\u003e\u003cspan\u003einputs: \u003c\/span\u003e\u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003efour \u003c\/span\u003e\u003cspan\u003esafe \u003c\/span\u003e\u003cspan\u003einputs \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003econnecting \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003edevices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSafe \u003c\/span\u003e\u003cspan\u003eOSSD \u003c\/span\u003e\u003cspan\u003eoutputs: \u003c\/span\u003e\u003cspan\u003eIncludes \u003c\/span\u003e\u003cspan\u003etwo \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003eoutputs \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eexternal \u003c\/span\u003e\u003cspan\u003edevices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eConfigurable \u003c\/span\u003e\u003cspan\u003eoutput \u003c\/span\u003e\u003cspan\u003egroups: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eeight \u003c\/span\u003e\u003cspan\u003elogical \u003c\/span\u003e\u003cspan\u003esafe \u003c\/span\u003e\u003cspan\u003eoutput \u003c\/span\u003e\u003cspan\u003egroups \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003efunctionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eProgrammable \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003elogic: \u003c\/span\u003e\u003cspan\u003eAllows \u003c\/span\u003e\u003cspan\u003emuting, \u003c\/span\u003e\u003cspan\u003etiming, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003elogic \u003c\/span\u003e\u003cspan\u003efunctions \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ebe \u003c\/span\u003e\u003cspan\u003econfigured \u003c\/span\u003e\u003cspan\u003eusing \u003c\/span\u003e\u003cspan\u003eSIMON+ \u003c\/span\u003e\u003cspan\u003esoftware.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail \u003c\/span\u003e\u003cspan\u003emounting: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eperformance: \u003c\/span\u003e\u003cspan\u003eSpecified \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eapplications \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eSIL \u003c\/span\u003e\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ePerformance \u003c\/span\u003e\u003cspan\u003eLevel \u003c\/span\u003e\u003cspan\u003ee, \u003c\/span\u003e\u003cspan\u003esubject \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ecorrect \u003c\/span\u003e\u003cspan\u003esystem \u003c\/span\u003e\u003cspan\u003edesign \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003econfiguration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eVAS-2A8L-KE4-8SE \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ereliability \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprecision \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003emonitoring \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eAS-Interface \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eapplications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":53206070821162,"sku":"VAS-2A8L-KE4-8SE","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_29832a1a-54b3-4d45-bdec-8ae1beb58868.webp?v=1792852140","url":"https:\/\/iqelectro.com\/products\/pepperl-fuchs-vas-2a8l-ke4-8se-as-interface-safety-monitor-controller","provider":"IQElectro","version":"1.0","type":"link"}