{"product_id":"pepperl-fuchs-vba-4e4a-g2-za-ea2-as-interface-sensor-actuator-module","title":"Pepperl+Fuchs VBA-4E4A-G2-ZA\/EA2 AS-Interface Sensor\/Actuator Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe Pepperl+Fuchs VBA-4E4A-G2-ZA\/EA2 is an AS-Interface sensor\/actuator module with four PNP inputs and four electronic PNP outputs. It connects field sensors and loads to an AS-Interface network, supplying the inputs from the bus and the outputs from an external auxiliary source.\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"3\" height=\"356\" style=\"width: 84.3603%; height: 427.601px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20.8125px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.85px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eIndustrial Communication \u0026amp; I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eVBA-4E4A-G2-ZA\/EA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eAS-Interface Sensor\/Actuator Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eHousing Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eG2 flat module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eNode Type \/ Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eA\/B node \/ S-7.A.E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eAS-Interface Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eV3.0; gateway specification ≥V3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eAS-Interface Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e26.5–31.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eRated Operating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e≤40 mA without sensors; maximum 220 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eAuxiliary Output Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e20–30 V DC PELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e4 PNP inputs for two-\/three-wire sensors; alternatively 2 four-wire PNP sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eSensor Supply Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e≤180 mA at ≤40°C; ≤140 mA at ≤60°C; overload and short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eInput Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eSignal delay \u0026lt;2 ms; signal frequency ≤250 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e4 electronic PNP outputs, overload and short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eOutput Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e0.5 A per output; 2 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e≥Auxiliary supply voltage −0.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003eYellow\/black flat cables via cable piercing; M12 field connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eHousing \/ Protection \/ Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003ePBT \/ IP67 \/ mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e−25 to +60°C; indoor use; ≤85% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.6209%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1709%;\"\u003e150 g (0.33 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eVBA-4E4A-G2-ZA\/EA2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe VBA-4E4A-G2-ZA\/EA2 is a G2 flat module configured as an A\/B node under AS-Interface specification V3.0. Its S-7.A.E profile requires a gateway supporting specification V3.0 or later. Cable-piercing contacts connect the yellow AS-Interface and black auxiliary-power flat cables, while M12 connectors provide field I\/O connections. The PBT housing incorporates indicators for bus power, auxiliary voltage, channel states, and faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFour Sensor Inputs: Accepts four two- or three-wire PNP sensors, or two four-wire PNP sensors.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFour Electronic Outputs: Provides four protected PNP outputs for compatible DC loads.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutput Capacity: Supports up to 0.5 A per output and 2 A total.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAS-Interface Communication: Operates as an A\/B node using AS-Interface V3.0 and profile S-7.A.E.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuxiliary Output Supply: Powers the outputs from an external 20–30 V DC PELV source.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eField Connections: Uses cable-piercing flat-cable contacts and M12 input\/output connectors.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDiagnostic Indicators: Displays power, channel states, communication faults, and overload conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtected Housing: Uses an IP67-rated PBT enclosure with mounting-plate installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe VBA-4E4A-G2-ZA\/EA2 delivers the reliability and precision required for distributed sensor and actuator interfacing in compatible AS-Interface automation systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":53008338256170,"sku":"VBA-4E4A-G2-ZA\/EA2","price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_489b0c92-b1dc-4f84-96f6-e13f400be503.webp?v=1792341194","url":"https:\/\/iqelectro.com\/products\/pepperl-fuchs-vba-4e4a-g2-za-ea2-as-interface-sensor-actuator-module","provider":"IQElectro","version":"1.0","type":"link"}