{"product_id":"phoenix-contact-2866705-quint-power-24-vdc-10-a-three-phase-din-rail-power-supply","title":"Phoenix Contact 2866705 QUINT POWER 24 VDC 10 A Three-Phase DIN Rail Power Supply","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cdiv class=\"flex flex-grow flex-col max-w-full\"\u003e\n\u003cdiv class=\"min-h-[20px] text-message flex flex-col items-start gap-3 whitespace-pre-wrap break-words [.text-message+\u0026amp;]:mt-5 overflow-x-auto\" data-message-id=\"9566a577-3fac-49c9-8dff-0eff58708b47\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert dark\"\u003e\n\u003cp\u003eThe Phoenix Contact 2866705 is a QUINT POWER industrial power supply designed for demanding single- and three-phase applications. It provides a regulated 24VDC output at 10 A with adjustable voltage and features Power Boost and Selective Fuse Breaking capabilities for starting high-inrush loads. Engineered for harsh environments, it includes preventive function monitoring, wide AC\/DC input ranges, and robust protection against transients and overload conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\n\u003cmeta charset=\"utf-8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhoenix Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2866705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQUINT POWER Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3× 400–500 VAC (–25% to +15%), 45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450–800 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e411 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3× 1.2 A @ 400 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 A @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93% (typical at 400 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–29.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Boost \/ Static Boost\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A (continuous to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFB Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A for 12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Ripple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 mV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;30 ms @ 400 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtective Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVaristor, gas spark gap, transient protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel\/Series Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor \"High\" signal (18–24 VDC), relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Switching Voltage (Relay)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNo-Load Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Load Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–25°C to +60°C (derating to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz (DC compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eInformation About 2866705\u003c\/span\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 2866705 belongs to the QUINT POWER series, a high-performance Phoenix Contact platform engineered for extreme industrial operating conditions. Its construction includes wide-range three-phase 400–500VAC input capability, as well as DC input from 450–800VDC, enabling global application and resilience to voltage fluctuations. The module provides preventive function monitoring—such as output voltage diagnostics and early fault detection—through transistor output and relay contacts for remote supervision. Typical usage includes power-critical automation systems, redundancy configurations, high-inrush loads, and installations requiring advanced overload behavior such as Power Boost, Static Boost, and Selective Fuse Breaking (SFB).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24VDC regulated output: Adjustable between 18–29.5 VDC for flexible load requirements.\u003c\/li\u003e\n\u003cli\u003e10 A rated output: Supports 240 W continuous power delivery.\u003c\/li\u003e\n\u003cli\u003eWide AC\/DC input capability: Accepts 3× 400–500VAC and 450–800VDC supplies.\u003c\/li\u003e\n\u003cli\u003ePower Boost (150% \/ 3× current): Enables reliable startup of high-inrush devices.\u003c\/li\u003e\n\u003cli\u003eSelective Fuse Breaking (SFB): Provides 60 A for 12 ms for rapid fuse tripping.\u003c\/li\u003e\n\u003cli\u003ePreventive function monitoring: Early warning via transistor output and relay contact.\u003c\/li\u003e\n\u003cli\u003eHigh efficiency (93%): Reduces heat generation and boosts system reliability.\u003c\/li\u003e\n\u003cli\u003eRobust protection: Includes varistors, gas discharge arresters, and transient suppression.\u003c\/li\u003e\n\u003cli\u003eParallel and serial operation: Supports redundancy or increased capacity configurations.\u003c\/li\u003e\n\u003cli\u003eWide temperature range: Operates from –25°C to +60°C with de-rating to 70°C.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting: Simplifies installation in control cabinets.\u003c\/li\u003e\n\u003cli\u003eLow residual ripple: Ensures stable supply for sensitive electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 2866705 delivers the reliability and precision required for critical industrial power distribution in harsh operating environments.\u003c\/p\u003e","brand":"Phoenix Contact","offers":[{"title":"Default Title","offer_id":47495818412330,"sku":"2866705","price":532.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/DSC_2273.jpg?v=1761591446","url":"https:\/\/iqelectro.com\/products\/phoenix-contact-2866705-quint-power-24-vdc-10-a-three-phase-din-rail-power-supply","provider":"IQElectro","version":"1.0","type":"link"}