{"product_id":"pja36080cu41a-square-d-powerpact-p-frame-800a-3-pole-molded-case-circuit-breaker-600vac","title":"PJA36080CU41A | Square D PowerPacT P-Frame 800A 3-Pole Molded Case Circuit Breaker, 600VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"247\" data-end=\"726\"\u003eThe Square D PJA36080CU41A is a PowerPacT P-frame molded case circuit breaker designed for high-capacity power distribution in industrial and commercial systems. This 3-pole circuit breaker is rated at 800 amps and 600 VAC, utilizing an electronic Micrologic trip unit to provide precise long-time and instantaneous protection. Built for I-Line mounting, the PJA36080CU41A supports secure installation in panelboards and switchboards requiring reliable feeder or main protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100.103%; height: 490.017px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003ePJA36080CU41A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries \/ Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003ePowerPacT P-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003ePJA (I-Line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eMicrologic 3.0 A, Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eLong-Time and Instantaneous (LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 39.2014px;\"\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 39.2014px;\"\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e25 kA @ 600 VAC, 65 kA @ 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eI-Line Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 39.2014px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 39.2014px;\"\u003eI-Line Line Side, Mechanical Lugs Load Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e3 × AWG 3\/0 to 500 kcmil (Cu\/Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003eUL 489, CSA, NOM, IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e12.86 in × 8.27 in × 8.05 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 38.7941%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2166%; height: 19.6007px;\"\u003e37 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003ePJA36080CU41A\u003c\/h4\u003e\n\u003cp data-start=\"758\" data-end=\"1353\"\u003eThe PJA36080CU41A is a Square D PowerPacT P-frame circuit breaker engineered for distribution-level protection in three-phase electrical systems. It features an electronic Micrologic 3.0 A trip unit with LI functionality, allowing accurate current measurement and dependable fault response. Designed with I-Line line-side connections and mechanical lugs on the load side, the breaker integrates efficiently into Schneider Electric I-Line architectures. With a 100% continuous current rating and compliance with UL, CSA, NOM, and IEC standards, it is suited for demanding electrical environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e800 Amp Rated Capacity: Supports high-load feeder and main distribution circuits\u003c\/li\u003e\n\u003cli\u003e3-Pole Configuration: Designed for three-phase ABC power systems\u003c\/li\u003e\n\u003cli\u003eMicrologic Electronic Trip Unit: Provides precise long-time and instantaneous protection\u003c\/li\u003e\n\u003cli\u003e100% Continuous Current Rating: Rated for full-load operation without derating\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated 25kA at 600 VAC and 65kA at 480 VAC\u003c\/li\u003e\n\u003cli\u003eI-Line Mounting Design: Enables fast, secure installation in I-Line panelboards\u003c\/li\u003e\n\u003cli\u003eIntegrated Push-to-Trip Button: Allows manual tripping for testing and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PJA36080CU41A delivers the reliability and precision required for high-capacity power distribution and protection applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51044799054122,"sku":"PJA36080CU41A","price":8199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/files_ca960ab5-d5e7-4ef2-8130-684d43090c4a.jpg?v=1768141554","url":"https:\/\/iqelectro.com\/products\/pja36080cu41a-square-d-powerpact-p-frame-800a-3-pole-molded-case-circuit-breaker-600vac","provider":"IQElectro","version":"1.0","type":"link"}