{"product_id":"potter-pad100-sm-addressable-speaker-module-with-dual-audio-inputs","title":"Potter PAD100-SM Addressable Speaker Module with Dual Audio Inputs","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Potter PAD100-SM is an addressable speaker module designed to switch audio signals within compatible Potter fire alarm systems. It uses one SLC loop address and can route one of two audio input channels to a single audio output channel for fire alarm voice notification applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"751\" style=\"width: 79.0684%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003ePotter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eFire Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003ePAD100-SM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eSpeaker Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eAddressable Speaker Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eSLC Address Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eOne SLC loop address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eAudio Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eTwo audio input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eAudio Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eOne audio output channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eOutput Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eSLC Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eClass A, Class B, or Class X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e24.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eMaximum SLC Standby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e240 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eMaximum SLC Alarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e240 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eOutput Channel Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e2 A @ 30 VDC; 0.5 A @ 25 VAC; 60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eInput Channel Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e25 VRMS, 70.7 VRMS, 30 VDC, 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eEOL Resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e5.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e32 to 120°F (0 to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e0 to 93% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eMaximum Modules per Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e4.17 × 4.17 × 1.14 in (106 × 106 × 29 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eUL Listed 2-1\/2-inch deep 2-gang box or 1-1\/2-inch deep 4-inch square box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eWiring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e12 to 22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003eRed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003ePotter IPA and AFC\/ARC series addressable fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5672%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0854%;\"\u003e0.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003ePAD100-SM\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe PAD100-SM is part of Potter’s PAD addressable fire alarm module series and is intended for audio switching applications. The module interfaces with Potter IPA and AFC\/ARC series addressable fire alarm control panels and uses the PAD Addressable Protocol. Its seven-position DIP switch provides address assignment from 1 through 127, with the audio input channels identified as sub-points of the module address. The unit supports Class A, Class B, and Class X SLC wiring and can be installed in compatible 4-inch square or double gang electrical boxes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAudio Switching: Switches one of two audio input channels to the module’s audio output channel.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAddressable Operation: Uses one SLC loop address within the compatible fire alarm system.\u003c\/li\u003e\n\u003cli\u003eDual Audio Inputs: Provides two audio input channels for connected amplifier sources.\u003c\/li\u003e\n\u003cli\u003eClass A\/B Output: Supports Class A or Class B wiring for the audio output channel.\u003c\/li\u003e\n\u003cli\u003eSLC Compatibility: Supports Class A, Class B, and Class X SLC wiring configurations.\u003c\/li\u003e\n\u003cli\u003eDIP Switch Addressing: Uses a seven-position DIP switch to assign an address from 1 to 127.\u003c\/li\u003e\n\u003cli\u003eLED Status Indication: Red LED indicates module polling and operating status.\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting: Installs in a UL Listed 2-gang box or compatible 4-inch square box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD100-SM delivers the reliability and precision required for addressable audio switching and voice notification applications in fire alarm systems.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":52570192740650,"sku":"PAD100-SM","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_6713301c-ceae-4782-be14-362752e7ae72.jpg?v=1789137429","url":"https:\/\/iqelectro.com\/products\/potter-pad100-sm-addressable-speaker-module-with-dual-audio-inputs","provider":"IQElectro","version":"1.0","type":"link"}