{"product_id":"potter-pad200-ductr-analog-addressable-duct-smoke-detector-with-relay","title":"Potter PAD200-DUCTR Analog Addressable Duct Smoke Detector with Relay","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Potter PAD200-DUCTR is an analog addressable duct smoke detector with an integrated relay for monitoring smoke in HVAC air ducts. It uses a photoelectric detector head and sampling tubes to identify smoke and combustion products moving through air-handling systems. The unit is designed for compatibility with Potter addressable fire alarm control panels in commercial, industrial, and residential applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.071%; height: 470.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePotter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePAD200-DUCTR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003eAnalog Addressable Duct Smoke Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePAD200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eDetector Head Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePAD200-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eDetector Head Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePhotoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e500 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eAir Velocity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e100–4,000 ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e10%–85%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePlastic backbox with clear plastic cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eHousing Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003eGray backbox with clear cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e13.5 × 4.5 × 2.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eRelay Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e8 A at 30 VDC; 10 A at 120 VAC; 10 A at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eSampling Tube Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e2.5 ft, 5 ft, or 10 ft STN-series tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eCompatible Control Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003ePotter IPA and AFC\/ARC series addressable fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eInstallation Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003eMounting template and two sheet metal screws included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003eUL 268A; CSFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.2523%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5339%;\"\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PAD200-DUCTR\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe PAD200-DUCTR belongs to Potter's PAD200 series of addressable duct smoke detection equipment. Its housing includes a PAD200-DD photoelectric detector head, a clear cover, and connections for the signaling line circuit and relay output. The detector supports air velocities from 100 to 4,000 feet per minute and uses a self-diagnostic test method for sensor verification. Its sampling system uses separately ordered STN-series intake tubes, while the included exhaust tube and mounting hardware support installation in suitable HVAC ductwork.\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog Addressable Detection: Communicates detector status through a compatible Potter addressable fire alarm system.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhotoelectric Sensor: Uses the PAD200-DD detector head to identify smoke particles in moving duct air.\u003c\/li\u003e\n\u003cli\u003eIntegrated Relay: Provides relay contacts for interfacing with compatible external equipment and control circuits.\u003c\/li\u003e\n\u003cli\u003eHVAC Duct Monitoring: Detects smoke and combustion products traveling through supply or return air ducts.\u003c\/li\u003e\n\u003cli\u003eWide Air Velocity Range: Supports airflow conditions from 100 to 4,000 feet per minute.\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostic Testing: Provides a sensor verification method for checking detector operation.\u003c\/li\u003e\n\u003cli\u003eClear Protective Cover: Allows visual inspection of the detector assembly and internal components.\u003c\/li\u003e\n\u003cli\u003eSampling Tube Compatibility: Uses STN-series sampling tubes available in multiple lengths for different duct widths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD200-DUCTR delivers the reliability and precision required for smoke detection and equipment interfacing in HVAC ductwork and compatible fire alarm systems.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":52589189562666,"sku":"PAD200-DUCTR","price":402.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l960_3d1663c2-3cd8-4b03-aa79-8bdd50022618.webp?v=1789240462","url":"https:\/\/iqelectro.com\/products\/potter-pad200-ductr-analog-addressable-duct-smoke-detector-with-relay","provider":"IQElectro","version":"1.0","type":"link"}