{"product_id":"qbaf1020-eaton-quicklag-qbaf-1-pole-20a-afci-thermal-magnetic-circuit-breaker","title":"QBAF1020 | Eaton Quicklag QBAF 1-Pole 20A AFCI Thermal Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Eaton QBAF1020 is a molded case arc fault circuit interrupter designed for single-phase branch circuits requiring enhanced fire protection. Rated at 20 amps and operating at 120\/240 volts, it provides dependable overcurrent and arc fault detection for residential and light commercial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9458%; height: 352.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eQBAF1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eQuicklag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eQBAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003e10 kA @ 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eLI – Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eAFCI (Arc Fault Circuit Interrupter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.4853%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.3678%; height: 19.6px;\"\u003eResidential and light commercial branch circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About QBAF1020\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe QBAF1020 is part of Eaton’s Quicklag Series and functions as a branch feeder arc fault circuit interrupter designed to reduce the risk of electrical fires in single-phase systems. Its single-pole, 20-amp design supports moderate-load circuits while providing essential AFCI protection to detect potentially hazardous arc faults. The bolt-on mounting configuration ensures secure installation in compatible panelboards, maintaining stable electrical contact. Equipped with LI trip characteristics and a thermal magnetic protection mechanism, the QBAF1020 responds effectively to both overload conditions and short-circuit events while adding an additional layer of arc fault detection for safety-critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAFCI functionality: Detects and interrupts arc faults to reduce the risk of electrical fires.\u003c\/li\u003e\n\u003cli\u003eSingle-pole construction: Supports individual branch circuits in residential and light commercial systems.\u003c\/li\u003e\n\u003cli\u003e20-amp rating: Provides reliable protection for moderate-load branch circuits.\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip: Offers long-time overload and instantaneous short-circuit response.\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating: Handles standard fault levels at 120 volts.\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting: Ensures secure and stable installation in Quicklag-compatible load centers.\u003c\/li\u003e\n\u003cli\u003eLI trip functions: Enhances circuit protection with long-time and instantaneous characteristics.\u003c\/li\u003e\n\u003cli\u003eQuicklag family design: Built to Eaton’s performance standards for dependable circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe QBAF1020 delivers the reliability and precision required for safeguarding branch circuits while providing critical arc fault protection in residential and light commercial electrical systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48527859450154,"sku":"QBAF1020","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_ce75e344-97b0-49cc-aa71-d7d24805eab3.webp?v=1770767022","url":"https:\/\/iqelectro.com\/products\/qbaf1020-eaton-quicklag-qbaf-1-pole-20a-afci-thermal-magnetic-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}