{"product_id":"r7795c1007-honeywell-electronic-programming-primary-burner-control","title":"R7795C1007 | Honeywell Electronic Programming Primary Burner Control","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"89\" data-end=\"403\"\u003eThe Honeywell R7795C1007 is a solid-state primary safety control designed for intermittent pilot burner systems with ultraviolet flame detection. It provides fast flame failure response and reliable electronic flame safeguard protection for commercial and industrial single- or dual-fuel burners.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eR7795C1007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003ePrimary Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eElectronic programming relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003ePilot Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eInterrupted pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlame Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eUltraviolet (UV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 39.1875px;\"\u003e\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 39.1875px;\"\u003e3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Switch Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003e10–15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrepurge Timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003ePlug-in, selectable (1.5 \/ 7 \/ 10 \/ 30 \/ 60 \/ 90 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eAirflow Switch Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eLine voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003eQ795A wiring subbase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003e-40 to +135 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.9444%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.692%; height: 19.5938px;\"\u003e2.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e R7795C1007\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe R7795C1007 is part of Honeywell’s electronic primary control lineup developed for robust flame safeguard protection in industrial combustion systems. It uses ultraviolet flame sensing with a purple-coded amplifier and requires a compatible plug-in prepurge timer to define purge duration. The control mounts on a Q795A wiring subbase and continuously monitors airflow from the start of prepurge through the run period. Built-in lockout logic prevents unsafe startup conditions if flame presence or flame-simulating faults are detected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary Flame Safeguard Control: Provides solid-state electronic protection for commercial and industrial burner applications.\u003c\/li\u003e\n\u003cli\u003eInterrupted Pilot Operation: Supports controlled ignition sequences for interrupted pilot burner systems.\u003c\/li\u003e\n\u003cli\u003eUltraviolet Flame Detection: Uses UV sensing for reliable flame supervision in demanding combustion environments.\u003c\/li\u003e\n\u003cli\u003eFast Flame Failure Response: 3-second response time minimizes unsafe fuel conditions during flame loss.\u003c\/li\u003e\n\u003cli\u003eSelectable Prepurge Timing: Requires plug-in timers offering multiple purge durations for application flexibility.\u003c\/li\u003e\n\u003cli\u003eAirflow Proving Capability: Monitors a line-voltage airflow switch throughout prepurge and burner operation.\u003c\/li\u003e\n\u003cli\u003eWide Temperature Rating: Designed for operation from -40 to +135 °F in harsh industrial settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe R7795C1007 delivers the reliability and precision required for safe interrupted pilot burner control in industrial combustion systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51055661613354,"sku":"R7795C1007","price":4884.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_c9ab7489-0da9-4724-9a62-06a045ee2d35.webp?v=1768473645","url":"https:\/\/iqelectro.com\/products\/r7795c1007-honeywell-electronic-programming-primary-burner-control","provider":"IQElectro","version":"1.0","type":"link"}