{"product_id":"r7824c1002-honeywell-flame-signal-amplifier-for-7800-series-relay-modules-with-dynamic-self-check","title":"R7824C1002 | Honeywell Flame Signal Amplifier For 7800 Series Relay Modules With Dynamic Self Check","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"397\" data-start=\"97\"\u003eThe Honeywell R7824C1002 is a flame signal amplifier engineered for integration with Honeywell 7800 Series relay modules to provide accurate flame supervision. It processes rectification-based flame signals and supports fast response times to maintain safe and stable burner operation.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eR7824C1002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eFlame Signal Amplifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlame Detection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eRectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eSelf-Check Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eDynamic Self-Check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 39.1875px;\"\u003e\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 39.1875px;\"\u003e0.8 sec or 3.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 39.1875px;\"\u003e\u003cstrong\u003eFlame Signal Strength Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 39.1875px;\"\u003e0.0 to 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 39.1875px;\"\u003e\u003cstrong\u003eCompatible Flame Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 39.1875px;\"\u003eC7024E, F Flame Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 39.1875px;\"\u003e\u003cstrong\u003eCompatible Primary Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 39.1875px;\"\u003eRM7824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003ePlug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003ePrinted circuit board edge connector (keyed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eSolid-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003eHoneywell 7800 Series Relay Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.7613%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8751%; height: 19.5938px;\"\u003e70 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e R7824C1002\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe R7824C1002 is a solid-state flame signal amplifier from Honeywell’s 7800 Series, designed specifically for rectification flame detection in automatically fired burner systems. It connects directly to compatible 7800 Series relay modules through a keyed printed circuit board edge connector, ensuring correct installation and reliable electrical contact. The amplifier incorporates dynamic self-check technology that continuously monitors the flame detector and internal electronics during operation. It is used with Honeywell flame detectors such as the C7024E and F models and operates in combination with RM7824 primary safety controls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDynamic Self-Check Technology: Continuously verifies flame detector operation and internal electronics for consistent system safety.\u003c\/li\u003e\n\u003cli\u003eSelectable Flame Failure Response Time: Supports 0.8 or 3.0 second response to accommodate different safety requirements.\u003c\/li\u003e\n\u003cli\u003eWide Signal Measurement Range: Monitors flame signal strength from 0.0 to 5.0 VDC for accurate diagnostics.\u003c\/li\u003e\n\u003cli\u003ePlug-In Design: Installs directly into 7800 Series relay modules using a keyed PCB edge connector.\u003c\/li\u003e\n\u003cli\u003eIntegrated Test Jacks: Allows direct measurement of flame signal voltage during commissioning and service.\u003c\/li\u003e\n\u003cli\u003eClear Visual Identification: Color-coded labels indicate flame detection type to reduce configuration errors.\u003c\/li\u003e\n\u003cli\u003eSolid-State Construction: Provides stable performance and long service life in industrial burner applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe R7824C1002 delivers the reliability and precision required for continuous flame monitoring and safety shutdown functions in industrial combustion control systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51056250749226,"sku":"R7824C1002","price":1032.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/R784-green.jpg?v=1768495436","url":"https:\/\/iqelectro.com\/products\/r7824c1002-honeywell-flame-signal-amplifier-for-7800-series-relay-modules-with-dynamic-self-check","provider":"IQElectro","version":"1.0","type":"link"}