{"product_id":"r8184g4009-honeywell-oil-primary-control-intermittent-ignition-45-sec-safety-timing","title":"R8184G4009 | Honeywell Oil Primary Control, Intermittent Ignition, 45-Sec Safety Timing","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"451\"\u003eThe Honeywell R8184G4009 is an oil burner primary safety control designed for intermittent ignition systems. It provides dependable shutdown protection, flame sensing, and low-voltage circuit control in residential and light commercial burner applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 313.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eR8184G4009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eOil Primary Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eSafety Switch Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e45 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eAmperage @ 120V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e7.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eAmperage @ 240V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e3.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eThermostat Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e0.2 A @ 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e-40 to 130°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e4 in. × 4 in. junction box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eIntermittent ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003eRelay protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.1009%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5844%; height: 19.6px;\"\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eR8184G4009\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe R8184G4009 is a Honeywell oil burner primary control engineered for intermittent ignition systems requiring reliable flame monitoring and safety shutdown functionality. Designed with an integral transformer, it powers the low-voltage control circuit while coordinating ignition, burner operation, and safety timing. Its solid-state flame-sensing circuit ensures accurate detection and fast response, supported by a 45-second safety switch timing for proper system protection. Installed on a standard 4 x 4 inch junction box and equipped with an external manual reset, the R8184G4009 offers dependable field serviceability and secure wiring through an exposed screw-terminal strip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil Primary Safety Control: Provides essential burner control and protection for intermittent ignition systems.\u003c\/li\u003e\n\u003cli\u003eIntegral Transformer: Supplies power to the low-voltage control circuit for stable system operation.\u003c\/li\u003e\n\u003cli\u003eSolid-State Flame Sensing: Ensures accurate and fast-response flame detection for improved burner safety.\u003c\/li\u003e\n\u003cli\u003e45-Second Safety Switch Timing: Supports proper ignition verification before lockout activation.\u003c\/li\u003e\n\u003cli\u003eManual Reset Safety Switch: External reset button enables safe, deliberate recovery after shutdown.\u003c\/li\u003e\n\u003cli\u003eExposed Screw Terminals: Allows straightforward low-voltage wiring and service access.\u003c\/li\u003e\n\u003cli\u003eWide Temperature Operating Range: Functions reliably from -40°F to 130°F in demanding environments.\u003c\/li\u003e\n\u003cli\u003eVersatile Mounting: Installs on standard 4×4 junction boxes; select models fit directly on burner housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe R8184G4009 delivers the reliability and precision required for safe and effective oil burner system control.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50935015309610,"sku":"R8184G4009","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/51E0E6MiSrL._AC_SX679.jpg?v=1765358069","url":"https:\/\/iqelectro.com\/products\/r8184g4009-honeywell-oil-primary-control-intermittent-ignition-45-sec-safety-timing","provider":"IQElectro","version":"1.0","type":"link"}