{"product_id":"rm7800l1053-honeywell-microprocessor-based-integrated-burner-control-120-vac","title":"RM7800L1053 | Honeywell Microprocessor-Based Integrated Burner Control, 120 VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"85\" data-end=\"376\"\u003eThe Honeywell RM7800L1053 is a microprocessor-based integrated burner control designed for automatically fired single-burner systems using gas, oil, coal, or combination fuels. It operates on 120 VAC and manages flame supervision, purge timing, and safety interlocks to ensure controlled burner operation. This controller includes an S7800 display for real-time system status and diagnostics.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eRM7800L1053\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eIntegrated Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eMicroprocessor-Based Burner Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eDisplay Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eYes (S7800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eMain Flame Establishing Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e10 seconds (intermittent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003ePilot Flame Establishing Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e4 seconds or 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003ePilot Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eInterrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eSecond Stage Pilot Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eIntermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003ePost Purge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eAirflow Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eUser selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eEarly Spark Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eFlame Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eLHL-LF and HF proven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eInterlocks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003eLockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e-40°F to 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2476%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.5331%;\"\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e RM7800L1053\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe RM7800L1053 is part of Honeywell’s RM7800 series of advanced burner management controls used in commercial and industrial combustion systems. It is engineered to coordinate ignition sequencing, flame establishment, and safety shutdowns through embedded microprocessor logic. The unit supports interrupted pilot operation with configurable flame establishing periods and integrates airflow verification and lockout interlocks for enhanced safety. Designed for harsh environments, it operates across a wide ambient temperature range and supports proven flame detection methods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-Based Control: Provides precise sequencing and monitoring of burner operation.\u003c\/li\u003e\n\u003cli\u003eMulti-Fuel Compatibility: Designed for gas, oil, coal, or combination fuel single-burner systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated Safety Interlocks: Supports lockout interlocks and proven LHL-LF and HF flame detection.\u003c\/li\u003e\n\u003cli\u003eConfigurable Flame Establishment: Supports 10-second main flame and 4- or 10-second pilot flame periods.\u003c\/li\u003e\n\u003cli\u003eInterrupted Pilot Operation: Includes intermittent second-stage pilot valve control.\u003c\/li\u003e\n\u003cli\u003eAirflow Check Selection: Allows user-selectable airflow verification for safe combustion.\u003c\/li\u003e\n\u003cli\u003eIncluded S7800 Display: Provides local diagnostics, status indication, and troubleshooting support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RM7800L1053 delivers the reliability and precision required for safe burner management and flame safeguard control in industrial combustion systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51055659843882,"sku":"RM7800L1053","price":2572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/RM7800L1053.png?v=1768473084","url":"https:\/\/iqelectro.com\/products\/rm7800l1053-honeywell-microprocessor-based-integrated-burner-control-120-vac","provider":"IQElectro","version":"1.0","type":"link"}