{"product_id":"schneider-electric-140ari03010-quantum-analog-input-module-8-channel-rtd-13-bit","title":"Schneider Electric 140ARI03010 Quantum Analog Input Module 8 Channel RTD 13-Bit","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"145\" data-end=\"525\"\u003eThe Schneider Electric 140ARI03010 is an analog input module designed for the Modicon Quantum automation platform to process temperature signals with high accuracy. It supports multiple RTD sensor types and delivers precise measurement for industrial process control applications. This module is ideal for monitoring temperature in manufacturing, energy, and automation systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140ARI03010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLCs\/Machine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (differential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD (Pt100, Pt200, Pt500, Pt1000, Ni100, Ni200, Ni500, Ni1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200°C to +850°C (depending on sensor type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e640 ms to 1200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation (Channel to Bus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1780 VAC \/ 2500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation (Between Channels)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Current Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, FM Class 1 Div 2, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 140ARI03010\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"559\" data-end=\"1157\"\u003eThe 140ARI03010 is a Schneider Electric analog input module from the Modicon Quantum series, developed for advanced PLC-based automation systems. It features eight differential input channels capable of handling various temperature probes including Pt and Ni sensors across wide measurement ranges. The module offers high-resolution signal processing with 13-bit accuracy and built-in diagnostics for fault detection such as broken wire conditions. Designed for industrial environments, it ensures reliable performance with strong electrical isolation and compliance with international standards.\u003c\/p\u003e\n\u003ch4\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8 Differential Analog Inputs: Supports simultaneous temperature monitoring across multiple channels\u003c\/li\u003e\n\u003cli\u003eWide Sensor Compatibility: Works with Pt100, Pt200, Pt500, Pt1000, and Ni-based probes\u003c\/li\u003e\n\u003cli\u003eHigh Measurement Accuracy: Provides precise readings with low error margins (±0.1°C)\u003c\/li\u003e\n\u003cli\u003e13-Bit Resolution: Ensures detailed signal acquisition for process control applications\u003c\/li\u003e\n\u003cli\u003eAdvanced Isolation Protection: Offers up to 1780 VAC isolation between channels and bus\u003c\/li\u003e\n\u003cli\u003eIntegrated Diagnostics: Detects faults such as broken wire and overrange conditions\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Provides visual feedback for channel activity and faults\u003c\/li\u003e\n\u003cli\u003eQuantum PLC Integration: Seamlessly integrates into Modicon Quantum automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 140ARI03010 delivers the reliability and precision required for accurate temperature monitoring and control in industrial automation systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51338051617066,"sku":"140ARI03010","price":511.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/files_b43aa549-f991-4688-90e9-e29c027228e2.jpg?v=1774901298","url":"https:\/\/iqelectro.com\/products\/schneider-electric-140ari03010-quantum-analog-input-module-8-channel-rtd-13-bit","provider":"IQElectro","version":"1.0","type":"link"}