{"product_id":"schneider-electric-527-npr-tac-xenta-netplus-router","title":"Schneider Electric 527-NPR TAC Xenta NetPlus Router","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe Schneider Electric 527-NPR is a TAC Xenta NetPlus Router designed to connect and manage communications between I\/NET building automation systems and Ethernet networks. It enables remote network access and routing for building control applications, supporting communication between I\/NET devices and connected management workstations. The unit is intended for building automation infrastr\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e \u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 443px; max-width: 100%; font-size: 14px;\" height=\"605\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eBuilding Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e527-NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eNetwork Router \/ Building Automation Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eTAC Xenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eNetPlus Router\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eI\/NET Building Automation Networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e24 V AC ±20%, 50\/60 Hz, or 19–40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eMaximum 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eTransformer Sizing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e10Base-T, RJ45, TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eRS-232 Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eRJ45, 8-pin; 2400–57600 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eRS-485 Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eAsynchronous serial interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eABS\/PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e0°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 3px 6px; width: 161.448px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 309.406px;\"\u003e0.2 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About 527-NPR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe 527-NPR belongs to the Schneider Electric TAC Xenta family of building automation network devices. It provides NetPlus Router functionality for I\/NET systems but does not include the web-based presentation capabilities available on the standard TAC Xenta 527. The device communicates with I\/NET systems over Ethernet and can be configured through a web browser. Its serial communication ports support local connections for configuration and communication with compatible equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\" data-pm-slice=\"3 1 []\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNetPlus Router Functionality: Provides network routing capabilities for compatible I\/NET building automation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet Connectivity: Connects the building automation system to an Ethernet network using TCP\/IP.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eI\/NET Integration: Supports communication between I\/NET devices and connected workstations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeb-Based Configuration: Allows configuration through a web browser.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSerial Communication: Provides RS-232 and RS-485 interfaces for supported communication and service connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding Automation Application: Designed for integration into building control and management infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact Enclosure: Supports installation in control panels and automation equipment locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDedicated Router Design: Provides NetPlus Router capabilities without the web-based presentation features of the standard TAC Xenta 527.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 527-NPR provides network connectivity and routing support for Schneider Electric building automation systems using I\/NET communications.\u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52965465424170,"sku":"527-NPR","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_a53a778a-6841-4e49-8432-1a05c96498f0.jpg?v=1792136739","url":"https:\/\/iqelectro.com\/products\/schneider-electric-527-npr-tac-xenta-netplus-router","provider":"IQElectro","version":"1.0","type":"link"}