{"product_id":"schneider-electric-ap4432-netshelter-30a-rack-automatic-transfer-switch","title":"Schneider Electric AP4432 NetShelter 30A Rack Automatic Transfer Switch","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Schneider Electric AP4432 is a 2U rack-mounted automatic transfer switch (ATS) designed to provide redundant power to network equipment and other critical IT loads. It features two independent 200\/208 V AC power inputs and automatically transfers connected equipment to the alternate source when the primary supply becomes unavailable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ch4\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 75%; height: 456px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003ePower Distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eAP4432\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eAutomatic Transfer Switches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eAPC NetShelter Rack ATS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eAutomatic Transfer Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eRack Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e2U\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e200\/208 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eMaximum Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e30 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eInput Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e2 × NEMA L6-30P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eOutput Receptacles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e16 × IEC C13, 2 × IEC C19\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eMaximum Load Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e4,992 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eTransfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e10 ms (high sensitivity); 12 ms (low sensitivity)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eInternal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003ePower Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e8 ft (2.44 m)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003eHorizontal rack mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e3.47 in (88.1 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e17.00 in (431.8 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e9.30 in (236.2 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 36.472946%; height: 19px;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.324649%; height: 19px;\"\u003e\u003cspan\u003e14.50 lb \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eInformation About AP4432\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AP4432 belongs to the APC NetShelter Rack ATS product range and supports a maximum input current of 30 A. It is equipped with two NEMA L6-30P input connections, sixteen IEC C13 output receptacles, and two IEC C19 output receptacles. Its automatic switching mechanism provides a transfer time of up to 10 ms under high-sensitivity settings and 12 ms under low-sensitivity settings. The unit is designed for horizontal installation in standard equipment racks and includes mounting brackets and an RS-232 configuration cable.\u003c\/span\u003e\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic Transfer Switching: Transfers connected loads between two independent power sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDual Power Inputs: Provides two NEMA L6-30P input connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMultiple Output Receptacles: Includes 16 IEC C13 and 2 IEC C19 outlets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e30 A Input Rating: Supports installations requiring high-capacity rack power distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e200\/208 V AC Operation: Designed for single-phase power systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eFast Transfer Time: Switches sources within 10 ms under high-sensitivity settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e2U Rack-Mount Design: Fits standard equipment racks with horizontal mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated Protection: Includes internal overload protection and supports external circuit-breaker protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe AP4432 delivers the reliability and precision required for redundant power distribution in server rooms, network cabinets, and data center infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan class=\"citation-409 citation-end-409\"\u003e\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53562849788202,"sku":"AP4432","price":2569.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_082d377b-4f74-4993-827b-2186c066e6c9.jpg?v=1794510844","url":"https:\/\/iqelectro.com\/products\/schneider-electric-ap4432-netshelter-30a-rack-automatic-transfer-switch","provider":"IQElectro","version":"1.0","type":"link"}