{"product_id":"schneider-electric-bga36050-circuit-breaker-quick-delivery","title":"BGA36050 | Schneider Electric PowerPacT B-Frame 3-Pole 50A I-Line Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Schneider Electric BGA36050 is a compact molded case circuit breaker designed to provide thermal-magnetic protection in commercial and industrial power distribution systems. It is rated at 50 amps and configured for three-pole operation at 600Y\/347 VAC with I-Line mounting.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eNew \/ Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eBGA36050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eSeries \/ Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003ePowerPacT B-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e525 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eSystem Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e600Y \/ 347 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e18 kA @ 600Y \/ 347 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eI-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eI-Line (Line), Mechanical Lugs (Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eWire Range (Cu\/Al)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eAWG 14 to AWG 2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eElectrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003ePhase Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eABC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eApplication Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003eHACR Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e5.39 in (137 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e3.19 in (81 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e3.50 in (89 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0428%;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8198%;\"\u003e2.90 lb (1.315 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About BGA36050\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe BGA36050 is a PowerPacT B-Frame circuit breaker engineered by Schneider Electric for reliable thermal-magnetic protection in space-efficient installations. It incorporates dual-break rotating contact technology to limit peak let-through current during short-circuit events. The breaker is designed with an I-Line line-side interface and load-side mechanical lugs to support flexible installation and system integration. It is commonly used in panelboards and distribution equipment where compact size, consistent interruption performance, and standardized mounting are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowerPacT B-Frame design: Combines compact construction with robust thermal-magnetic circuit protection.\u003c\/li\u003e\n\u003cli\u003e50 amp current rating: Suitable for branch and feeder circuits in commercial and industrial systems.\u003c\/li\u003e\n\u003cli\u003eThree-pole configuration: Supports balanced protection of three-phase power circuits.\u003c\/li\u003e\n\u003cli\u003e18 kA interrupting capacity: Provides effective fault interruption at 600Y\/347 VAC systems.\u003c\/li\u003e\n\u003cli\u003eDual-break rotating contacts: Reduces peak current and enhances short-circuit performance.\u003c\/li\u003e\n\u003cli\u003eI-Line mounting interface: Enables fast, secure installation in compatible Schneider Electric panel systems.\u003c\/li\u003e\n\u003cli\u003eIntegral push-to-trip button: Allows manual tripping for testing and maintenance operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BGA36050 delivers the reliability and precision required for compact, high-performance circuit protection in Schneider Electric PowerPacT B-Frame electrical distribution systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48504871321898,"sku":"BGA36050","price":612.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/PP-B_I-Line_3_REP_DA21_1500x1500_1083aaf1-5358-49b1-b863-822f9630bdef.jpg?v=1716393692","url":"https:\/\/iqelectro.com\/products\/schneider-electric-bga36050-circuit-breaker-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}