{"product_id":"schneider-electric-fal34070-circuit-breaker-ready-to-ship","title":"FAL34070 | Schneider Electric Square D FAL Series 3-Pole 70A 480V Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Schneider Electric Square D FAL34070 is a three-pole molded case circuit breaker designed for reliable overcurrent protection in three-phase electrical distribution systems. It operates at 70 amps and 480 volts with standard interrupting capacity and unit-mount construction.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%; height: 472.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eNew \/ Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eFAL34070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 21.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 21.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries \/ Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eFAL Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eFAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eLine Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003ePhase Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eABC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaking Capacity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eA (Standard Interrupting Capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e18 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eLI (Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eUnit Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eMagnetic Hold Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eMagnetic Tripping Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e1450 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eLine and Load Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eTerminal Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eAL100FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003eHACR Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e6.4 in (162.56 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e4.5 in (114.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.5588%; height: 19.6px;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1164%; height: 19.6px;\"\u003e4.13 in (104.90 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FAL34070\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FAL34070 is a molded case circuit breaker from the Schneider Electric Square D FAL series engineered for dependable protection of three-phase electrical systems. It incorporates a thermal-magnetic LI trip unit that provides coordinated long-time overload protection and instantaneous short-circuit response. The breaker is designed with feed-thru capability and includes line and load side lug terminals to support flexible installation within distribution panels. It is commonly applied in commercial and industrial environments where standard interrupting capacity and fixed trip characteristics are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole configuration: Provides coordinated protection for three-phase electrical circuits.\u003c\/li\u003e\n\u003cli\u003e70 amp current rating: Suitable for feeder and branch circuit protection in industrial applications.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic LI trip unit: Combines long-time overload sensing with instantaneous short-circuit protection.\u003c\/li\u003e\n\u003cli\u003e18 kA interrupting capacity: Meets standard fault interruption requirements at 480 VAC.\u003c\/li\u003e\n\u003cli\u003eFeed-thru capable design: Allows versatile integration into electrical distribution layouts.\u003c\/li\u003e\n\u003cli\u003eUnit-mount construction: Enables direct mounting within panels and switchgear assemblies.\u003c\/li\u003e\n\u003cli\u003eHACR rated application: Approved for heating, air conditioning, and refrigeration circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FAL34070 delivers the reliability and precision required for consistent overcurrent protection in Schneider Electric Square D FAL series three-phase power distribution systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48505344164138,"sku":"FAL34070","price":929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/FAL-34_5906a4a9-49fd-47b7-9993-ca9039388757.webp?v=1716396868","url":"https:\/\/iqelectro.com\/products\/schneider-electric-fal34070-circuit-breaker-ready-to-ship","provider":"IQElectro","version":"1.0","type":"link"}