{"product_id":"schneider-electric-fcp34060-circuit-breaker-responsive-support","title":"FCP34060 | Schneider Electric Three Pole Thermal Magnetic Molded Case Circuit Breaker 60A 480V","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"376\" data-start=\"85\"\u003eThe Schneider Electric FCP34060 is a three pole molded case circuit breaker designed to provide reliable protection for three-phase power distribution systems. It delivers thermal magnetic protection with long-time and instantaneous trip functions for controlled operation in industrial and commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eFCP34060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eFCL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003e65 kAIC @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eLong-Time and Instantaneous (LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eLine and Load Side Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eStandards \/ Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003eUL, CSA, NOM, IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8195%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8169%;\"\u003e7 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e FCP34060\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FCP34060 is part of the Schneider Electric FCP Series, engineered for molded case circuit breaker applications requiring high interrupting capacity and dependable protection. This breaker supports three-phase electrical systems with a continuous current rating of 60 amps at 480 VAC. It incorporates a thermal magnetic trip unit that provides coordinated overload protection and instantaneous short-circuit response through long-time and instantaneous trip functions. The FCL frame construction and feed-thru connection design allow secure installation in panelboards and switchgear used in industrial power distribution environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Magnetic Protection Unit: Combines thermal overload sensing with instantaneous magnetic tripping to protect circuits from sustained overcurrent and short-circuit faults.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 65 kAIC at 480 V, enabling safe interruption of high fault currents in demanding electrical systems.\u003c\/li\u003e\n\u003cli\u003eThree Pole Configuration: Ensures balanced protection across all phases in three-phase power distribution networks.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection Design: Supports straight-through wiring using line and load side lugs for efficient panel layouts.\u003c\/li\u003e\n\u003cli\u003eFCL Frame Construction: Engineered for mechanical durability and consistent electrical performance under load and fault conditions.\u003c\/li\u003e\n\u003cli\u003eWide Standards Compliance: Approved to UL, CSA, NOM, and IEC standards for use in regulated industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCP34060 delivers the reliability and precision required for protecting three-phase power distribution circuits in commercial and industrial installations.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51071384813866,"sku":"FCP34060","price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_738ca410-d2aa-4786-ac48-48082b1c45ec.webp?v=1768990385","url":"https:\/\/iqelectro.com\/products\/schneider-electric-fcp34060-circuit-breaker-responsive-support","provider":"IQElectro","version":"1.0","type":"link"}