{"product_id":"schneider-electric-fh36060-circuit-breaker-trusted-supplier","title":"FH36060 | Schneider Electric Square D I-Line Type FH 3-Pole Circuit Breaker 60 A 600 Vac","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Schneider Electric Square D FH36060 is a 3-pole I-Line molded case circuit breaker rated at 60 A for 600 Vac power systems. It uses thermal-magnetic trip technology to provide reliable overload and short-circuit protection in industrial distribution applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eFH36060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eSeries \/ Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eFH, I-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e25 kA at 480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eBreaking Capacity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eMagnetic Hold Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eMagnetic Tripping Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e1450 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eI-Line plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003ePhase Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eABC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eTerminal Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eAL100FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eApplication Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003eHACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e6.4 in (162.56 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e4.5 in (114.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.2057%;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4696%;\"\u003e4.13 in (104.90 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FH36060\u003c\/h4\u003e\n\u003cp\u003eThe FH36060 is an I-Line style circuit breaker from Schneider Electric’s Square D FH series, engineered for dependable protection in industrial power distribution systems. Its molded case construction and I-Line plug-in design allow rapid installation in compatible panelboards while maintaining secure electrical connections. The breaker incorporates a thermal-magnetic trip unit to manage both sustained overloads and instantaneous short-circuit conditions. Designed for high-demand environments, it meets application requirements such as HACR rating and supports consistent performance under fault conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI-Line FH series design: Developed for fast plug-in installation in Square D I-Line panelboards.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit: Provides coordinated protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003e60 A, 3-pole configuration: Supports three-phase industrial and commercial distribution circuits.\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity: Rated to interrupt up to 25 kA at 480 Vac for demanding fault scenarios.\u003c\/li\u003e\n\u003cli\u003eHACR rated construction: Suitable for heating, air conditioning, and refrigeration equipment circuits.\u003c\/li\u003e\n\u003cli\u003eRobust molded case housing: Ensures mechanical durability and reliable operation in industrial environments.\u003c\/li\u003e\n\u003cli\u003eDefined magnetic trip characteristics: Supports predictable short-circuit response and system coordination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FH36060 delivers the reliability and precision required for secure protection of three-phase power distribution systems in industrial applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48744392524074,"sku":"FH36060","price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/FH36060-1_8265b3e0-eaeb-4f83-9ff3-75aa8731f19b.webp?v=1718793621","url":"https:\/\/iqelectro.com\/products\/schneider-electric-fh36060-circuit-breaker-trusted-supplier","provider":"IQElectro","version":"1.0","type":"link"}