{"product_id":"schneider-electric-hdl36100-circuit-breaker-secure-packaging","title":"HDL36100 | Schneider Electric PowerPacT H-Frame 3-Pole Molded Case Circuit Breaker 100 A 600 Vac","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"420\" data-start=\"119\"\u003eThe Schneider Electric HDL36100 is a 3-pole PowerPacT H-Frame molded case circuit breaker rated at 100 A for distribution line protection. It uses a thermal-magnetic trip unit to provide reliable overload and short-circuit protection in low-voltage industrial and commercial systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eHDL36100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eSeries \/ Product Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003ePowerPacT H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eH-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e3t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e690 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e14 kA at 600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eBreaking Capacity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eMagnetic Tripping Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e1700 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eMagnetic Hold Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e900 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eSuitability for Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eUnit mount lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eAWG 14…3\/0 Al\/Cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003eOFF indication, trip indicator (green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e6.42 in (163 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e4.09 in (104 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e3.39 in (86 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8644%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8109%;\"\u003e4.85 lb (2.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About HDL36100\u003c\/h4\u003e\n\u003cp\u003eThe HDL36100 is a molded case circuit breaker from Schneider Electric’s PowerPacT H-Frame family, designed for dependable protection of low-voltage distribution systems. Its construction incorporates dual-break rotating contacts that reduce peak let-through current during short-circuit events. The breaker supports unit-mount installations with lug terminations on both the line and load sides for flexible system integration. Designed in accordance with IEC standards, it delivers consistent performance in demanding industrial and commercial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowerPacT H-Frame design: Engineered for robust performance in low-voltage distribution and feeder protection applications.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit: Provides coordinated protection against sustained overloads and instantaneous short circuits.\u003c\/li\u003e\n\u003cli\u003eDual-break rotating contacts: Minimize peak current stresses during short-circuit faults to enhance system reliability.\u003c\/li\u003e\n\u003cli\u003e100 A, 3-pole configuration: Supports three-phase power systems used in industrial and commercial installations.\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity: Rated to interrupt up to 14 kA at 600 Vac for effective fault mitigation.\u003c\/li\u003e\n\u003cli\u003eIntegrated status indication: Includes OFF position and green trip indicator for clear breaker status visibility.\u003c\/li\u003e\n\u003cli\u003eUnit-mount lug connections: Enables secure conductor termination and adaptable installation layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HDL36100 delivers the reliability and precision required for safe and efficient protection of three-phase power distribution circuits.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48744310440234,"sku":"HDL36100","price":635.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/HDL36100_DA19_1500x1500_f7376e2b-3552-4bbb-9ff5-37a25dc45f46.jpg?v=1718792550","url":"https:\/\/iqelectro.com\/products\/schneider-electric-hdl36100-circuit-breaker-secure-packaging","provider":"IQElectro","version":"1.0","type":"link"}