{"product_id":"schneider-electric-hga36110-circuit-breaker-ships-fast","title":"HGA36110 | Schneider Electric PowerPact H 3-Pole 110A Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"376\" data-start=\"85\"\u003eThe Schneider Electric HGA36110 is a PowerPact H molded case circuit breaker designed for reliable power distribution and circuit protection in commercial and industrial electrical systems. It features a thermal-magnetic trip unit and high interrupting capacity to protect against overloads and short circuits. This three-pole circuit breaker is engineered for dependable performance across AC and DC applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 450.657px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eHGA36110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003ePowerPact H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e110 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eUp to 690 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eUp to 65 kA @ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eI-Line Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eI-Line (Line), Lugs (Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e6.4 in (163 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e4.09 in (104 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e3.4 in (86 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003eIP40 (Front Cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3697%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.411%; height: 19.5938px;\"\u003e4.9 lb (2.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e HGA36110\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe HGA36110 is part of Schneider Electric’s PowerPact H product line, developed to meet demanding distribution and protection requirements. It is designed for use in three-phase systems and supports both AC and DC voltage ratings across a wide range of operating conditions. The breaker incorporates thermal-magnetic trip technology to provide consistent protection against overload and fault currents. Its construction supports I-Line mounting and compatibility with auxiliary and communication accessories for advanced system integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowerPact H Series Design: Engineered for high-performance power distribution applications.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit: Provides dependable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated up to 65 kA at 240 VAC for robust fault protection.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Suitable for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003eWide Voltage Compatibility: Supports AC and DC operational voltages across multiple standards.\u003c\/li\u003e\n\u003cli\u003eI-Line Mounting Capability: Enables efficient installation in Schneider Electric panel systems.\u003c\/li\u003e\n\u003cli\u003eAccessory Support: Compatible with auxiliary switches, alarm switches, and communication modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HGA36110 delivers the reliability and precision required for industrial and commercial power distribution and circuit protection applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51071256592682,"sku":"HGA36110","price":2929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_448b0033-25dd-4921-85a6-ff65892cc362.webp?v=1768981735","url":"https:\/\/iqelectro.com\/products\/schneider-electric-hga36110-circuit-breaker-ships-fast","provider":"IQElectro","version":"1.0","type":"link"}