{"product_id":"schneider-electric-jgl36150-circuit-breaker-fast-shipping","title":"JGL36150 | Schneider Electric PowerPacT J-Frame 3-Pole Molded Case Circuit Breaker 150 A 600 Vac","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"398\" data-start=\"119\"\u003eThe Schneider Electric JGL36150 is a 3-pole PowerPacT J-Frame molded case circuit breaker rated at 150 A for low-voltage distribution systems. It uses thermal-magnetic trip technology to provide dependable overload and short-circuit protection at up to 600 Vac.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eJGL36150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003ePowerPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003ePowerPacT J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eJ-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e600 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eBreaking Capacity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e18 kA at 600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eMagnetic Tripping Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e1750 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eMagnetic Hold Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e750 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eOverload, Short-circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eSuitability for Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eUnit mount lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eTerminal Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eAL175JD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003eAWG 4…4\/0 Al\/Cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e221.27 lbf·in (25 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003ePower Wire Strip Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e0.98 in (25 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e7.52 in (191 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e4.09 in (104 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e3.39 in (86 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0026%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.86%;\"\u003e5.29 lb (2.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About JGL36150 \u003c\/h4\u003e\n\u003cp\u003eThe JGL36150 is a molded case circuit breaker from Schneider Electric’s PowerPacT J-Frame family, engineered for reliable protection of low-voltage distribution and feeder circuits. Its construction incorporates dual-break rotating contacts that reduce peak let-through current during short-circuit conditions. The breaker supports unit-mount installation with lug connections on both line and load sides for secure system integration. Designed in accordance with IEC standards, it is suitable for demanding industrial and commercial electrical environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowerPacT J-Frame design: Developed for compact, high-performance protection in distribution line applications.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit: Provides coordinated response to sustained overloads and instantaneous short-circuit faults.\u003c\/li\u003e\n\u003cli\u003e150 A, 3-pole configuration: Supports three-phase power systems used in commercial and industrial installations.\u003c\/li\u003e\n\u003cli\u003eDual-break rotating contacts: Minimize peak current stresses to enhance system safety and equipment longevity.\u003c\/li\u003e\n\u003cli\u003e18 kA interrupting capacity: Ensures effective fault interruption at 600 Vac operating voltage.\u003c\/li\u003e\n\u003cli\u003eUnit-mount lug terminals: Enable secure termination of aluminum or copper conductors.\u003c\/li\u003e\n\u003cli\u003eIntegrated trip indication: Provides clear OFF and trip status visibility for maintenance and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe JGL36150 delivers the reliability and precision required for consistent protection of three-phase low-voltage power distribution systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48745521348906,"sku":"JGL36150","price":1129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/JGL36150-1_b8b53ab5-e6e6-413e-aade-a24de47b8334.webp?v=1718818645","url":"https:\/\/iqelectro.com\/products\/schneider-electric-jgl36150-circuit-breaker-fast-shipping","provider":"IQElectro","version":"1.0","type":"link"}