{"product_id":"schneider-electric-mnb-v2-2-micronet-bacnet-vav-deluxe-controller-53-lb-in","title":"Schneider Electric MNB-V2-2 MicroNet BACnet VAV Deluxe Controller 53 lb-in","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-path-to-node=\"1,0,0\"\u003e\u003cspan class=\"citation-309 citation-end-309\"\u003eThe Schneider Electric MNB-V2-2 is a MicroNet BACnet VAV Deluxe Controller designed for comprehensive air volume management in commercial buildings.\u003csup class=\"superscript\" data-turn-source-index=\"21\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-308 citation-end-308\"\u003eFeaturing an integrated 53 lb-in actuator and self-calibrating pressure transducer, this unit regulates single-duct VAV terminal boxes with high precision.\u003csup class=\"superscript\" data-turn-source-index=\"22\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e It provides robust HVAC control and intelligent airflow balancing across networked automated facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"4\" style=\"width: 75.7803%; height: 284px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,1,0,0\"\u003e\u003cb data-path-to-node=\"34,1,0,0\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,1,1,0\"\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,2,0,0\"\u003e\u003cb data-path-to-node=\"34,2,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,2,1,0\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,3,0,0\"\u003e\u003cb data-path-to-node=\"34,3,0,0\" data-index-in-node=\"0\"\u003eCategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,3,1,0\"\u003eHVAC \u0026amp; Refrigeration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,4,0,0\"\u003e\u003cb data-path-to-node=\"34,4,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,4,1,0\"\u003eMNB-V2-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,5,0,0\"\u003e\u003cb data-path-to-node=\"34,5,0,0\" data-index-in-node=\"0\"\u003eSubcategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,5,1,0\"\u003eVAV Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,6,0,0\"\u003e\u003cb data-path-to-node=\"34,6,0,0\" data-index-in-node=\"0\"\u003eController Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,6,1,0\"\u003eMicroNet BACnet Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,7,0,0\"\u003e\u003cb data-path-to-node=\"34,7,0,0\" data-index-in-node=\"0\"\u003eActuator Torque\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,7,1,0\"\u003e53 lb-in (6 Nm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,8,0,0\"\u003e\u003cb data-path-to-node=\"34,8,0,0\" data-index-in-node=\"0\"\u003ePressure Transducer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,8,1,0\"\u003eSelf-Calibrating Differential\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,9,0,0\"\u003e\u003cb data-path-to-node=\"34,9,0,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,9,1,0\"\u003eBACnet MS\/TP \/ S-Link Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,10,0,0\"\u003e\u003cb data-path-to-node=\"34,10,0,0\" data-index-in-node=\"0\"\u003ePower Input\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,10,1,0\"\u003e20.4 to 30 VAC (24V AC Nom.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,11,0,0\"\u003e\u003cb data-path-to-node=\"34,11,0,0\" data-index-in-node=\"0\"\u003eEnclosure Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,11,1,0\"\u003eUL 94-5VA Plenum Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.7965%;\"\u003e\u003cspan data-path-to-node=\"34,12,0,0\"\u003e\u003cb data-path-to-node=\"34,12,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.8198%;\"\u003e\u003cspan data-path-to-node=\"34,12,1,0\"\u003e3.20 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eMNB-V2-2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"citation-307 citation-end-307\"\u003eThe MNB-V2-2 is part of the MicroNet BACnet family built to deliver pressure-independent or pressure-dependent terminal unit control.\u003csup class=\"superscript\" data-turn-source-index=\"23\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e It integrates a self-calibrating differential pressure transducer and a direct-mount 24V AC actuator into a single plenum-rated enclosure. Designed with S-Link bus compatibility, it connects effortlessly to MicroNet MN-Sx smart wall sensors for local setpoint and humidity monitoring. This controller operates on BACnet MS\/TP networks, offering DIP-switch MAC addressing and versatile universal inputs for auxiliary HVAC sensing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"32,0,0\" id=\"p-rc_97adfa1e80315665-174\"\u003e\u003cspan class=\"citation-306 citation-end-306\"\u003eIntegrated 53 lb-in Actuator: Provides strong rotational torque to drive heavy damper shafts across a 0 to 90 degree stroke.\u003csup class=\"superscript\" data-turn-source-index=\"24\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"32,1,0\"\u003eSelf-Calibrating Transducer: Maintains long-term differential pressure accuracy without requiring manual zero-point adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"32,2,0\"\u003eS-Link Sensor Interface: Connects to MN-Sx room sensors via two-wire unshielded cable for temperature and humidity data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"32,3,0\"\u003eBACnet MS\/TP Communication: Supports open-protocol network integration with selectable baud rates up to 76.8 kbps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"32,4,0\" id=\"p-rc_97adfa1e80315665-175\"\u003e\u003cspan class=\"citation-305 citation-end-305\"\u003eManual Override Pushbutton: Allows technicians to position the damper manually during testing and balancing routines.\u003csup class=\"superscript\" data-turn-source-index=\"25\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"32,5,0\"\u003eUniversal Analog Inputs: Accepts 0-10V, 4-20mA, thermistor, and dry contact inputs for multi-point sensor integration.\u003c\/p\u003e\n\u003cp data-path-to-node=\"32,5,0\"\u003eThe MNB-V2-2 delivers the reliability and precision required for advanced VAV terminal box control and building automation networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53098954588458,"sku":"MNB-V2-2","price":1187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_6bbc2d8e-5fae-4711-935b-b6be3ce90b3d.webp?v=1792685402","url":"https:\/\/iqelectro.com\/products\/schneider-electric-mnb-v2-2-micronet-bacnet-vav-deluxe-controller-53-lb-in","provider":"IQElectro","version":"1.0","type":"link"}