{"product_id":"schneider-electric-nq442l2c-225a-42-space-panelboard-interior","title":"Schneider Electric NQ442L2C 225A 42-Space Panelboard Interior","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"451\" data-start=\"0\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Schneider Electric NQ442L2C is an NQ Series panelboard interior designed for main lug electrical distribution systems in commercial and industrial applications. Rated for 225 A, it features a durable copper bus, 42 pole spaces, and supports three-phase, four-wire systems operating at 240 VAC or 48 VDC.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNQ442L2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Center Circuit Breaker Panelboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanelboard Interior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Branch Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQOB, QOB-VH, QHB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 VAC \/ 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Terminal Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLug, AWG 6–350 kcmil Aluminum\/Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 in (965.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 in (508 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Depth (NEMA 1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.75 in (146.05 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Depth (NEMA 3R\/5\/12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 in (165.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 369-HI-0-M-0-0\u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"1074\" data-start=\"590\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe NQ442L2C is part of Schneider Electric's NQ Series of panelboard interiors engineered for dependable branch circuit distribution. Designed for main lug applications, it accommodates up to 42 pole spaces and supports QOB, QOB-VH, and QHB branch circuit breakers. Its copper busbar construction provides excellent electrical conductivity and long-term durability, while the 225 A rating makes it suitable for a wide range of commercial and industrial installations. Compatible with three-phase, four-wire systems, the NQ442L2C delivers flexible and efficient power distribution for panelboard assemblies.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1661\" data-start=\"979\"\u003e\n\u003cli data-end=\"1070\" data-start=\"979\" data-section-id=\"8nyhns\"\u003e225 A Current Rating: Supports commercial and industrial electrical distribution systems.\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1156\" data-start=\"1071\" data-section-id=\"11hsjeg\"\u003eMain Lug Configuration: Designed for panelboards using main lug power distribution.\u003c\/li\u003e\n\u003cli data-end=\"1240\" data-start=\"1157\" data-section-id=\"r6ael4\"\u003e42 Pole Spaces: Accommodates numerous branch circuits for flexible system design.\u003c\/li\u003e\n\u003cli data-end=\"1325\" data-start=\"1241\" data-section-id=\"ucmfnq\"\u003eCopper Busbar: Provides superior electrical conductivity and corrosion resistance.\u003c\/li\u003e\n\u003cli data-end=\"1399\" data-start=\"1326\" data-section-id=\"mgjym0\"\u003eThree-Phase Operation: Designed for 3-phase, 4-wire electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1479\" data-start=\"1400\" data-section-id=\"1ji61h5\"\u003eBreaker Compatibility: Supports QOB, QOB-VH, and QHB branch circuit breakers.\u003c\/li\u003e\n\u003cli data-end=\"1560\" data-start=\"1480\" data-section-id=\"1mfw5kv\"\u003eMultiple Voltage Ratings: Operates with 240 VAC and 48 VDC electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1661\" data-start=\"1561\" data-section-id=\"1rmumkn\"\u003eRugged Panelboard Interior: Engineered for reliable long-term operation in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1845\" data-start=\"1663\"\u003eThe NQ442L2C delivers the reliability and flexibility required for commercial and industrial panelboard installations, branch circuit distribution, and power management applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48795029078314,"sku":"NQ442L2C","price":669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/NQ442L2C_DA19_1500x1500_50bd40ca-1c97-4d21-ac17-fd67cacddd4d.jpg?v=1719391116","url":"https:\/\/iqelectro.com\/products\/schneider-electric-nq442l2c-225a-42-space-panelboard-interior","provider":"IQElectro","version":"1.0","type":"link"}