{"product_id":"schneider-electric-pq4620g-i-line-fusible-busway-plug-in-disconnect-200-a-three-phase-four-wire","title":"Schneider Electric PQ4620G I-Line Fusible Busway Plug-In Disconnect, 200 A, Three-Phase, Four-Wire","description":"\u003ch4\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/h4\u003e\n\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/h4\u003e\n\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Schneider Electric PQ4620G is a 200 A fusible busway plug-in unit for supplying branch circuits from compatible Square D I-Line distribution systems. It combines manual disconnection with fuse provisions for three-phase, four-wire applications, including 277\/480 V AC systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePQ4620G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D PQ \/ I-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFusible busway plug-in disconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal System Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e277\/480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour-pole, four-wire plus ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusway Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Fuse Arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass H fuse spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass R Rejection Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHRK1020; field installation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass J Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires relocation of the load-side fuse base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMatching Square D I-Line and I-Line II plug-in busway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PQ4620G\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe PQ4620G is part of the Square D PQ fusible bus-plug range. Its enclosed assembly incorporates a manually operated switch and three fuse positions. The four-pole connection arrangement includes a neutral connection and a separate ground provision. Compatible fuse configurations allow the unit to support protected power takeoffs for commercial and industrial equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBusway Power Takeoff: Connects a branch circuit to a compatible I-Line busway plug-in location.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Capacity: Provides a 200 A unit rating for appropriately configured loads.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFour-Wire Connection: Accommodates three-phase power conductors, neutral, and ground.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFusible Protection: Provides three fuse positions for protecting the phase circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManual Isolation: Includes a switching mechanism for disconnecting the connected load.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClass R Conversion: Accepts the specified HRK1020 rejection kit for Class R fuse use.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClass J Conversion: Supports Class J fuse spacing by repositioning the load-side fuse base as instructed.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe PQ4620G delivers the reliability and precision required for fused branch-circuit disconnection and power distribution from compatible busway systems. \u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53610353426730,"sku":"PQ4620G","price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_2b4e828f-daa1-47a7-bb63-106921018034.jpg?v=1794758767","url":"https:\/\/iqelectro.com\/products\/schneider-electric-pq4620g-i-line-fusible-busway-plug-in-disconnect-200-a-three-phase-four-wire","provider":"IQElectro","version":"1.0","type":"link"}