{"product_id":"schneider-electric-qo230gfi-circuit-breaker-responsive-support","title":"QO230GFI | Schneider Electric QO Series 2-Pole 30A 120V GFI Thermal Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Schneider Electric QO230GFI is a molded case circuit breaker designed to provide both overcurrent protection and Class A ground-fault interruption in single-phase electrical systems. Rated for 120 volts and 30 amps, it supports residential and light commercial applications where enhanced personnel protection is required.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9458%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eQO230GFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eQO Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eQO-GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eAdditional Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eClass A Ground Fault Interruption (GFI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eLI – Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003e10 kA @ 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eQO Series load centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.1216%;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7314%;\"\u003eGround Fault Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About QO230GFI\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe QO230GFI is part of Schneider Electric’s QO Series and provides essential ground fault protection in addition to standard overload and short-circuit protection. Designed for single-phase 120-volt systems, it supports a 30-amp load and installs easily using a plug-in configuration compatible with QO load centers. Its Class A GFI functionality is engineered to detect low-level ground faults typical of shock hazards, making it well suited for areas requiring enhanced electrical safety. The breaker’s thermal magnetic LI trip mechanism ensures dependable operation under both sustained overload and rapid fault conditions, while its 10 kA interrupt rating supports standard residential and commercial fault-clearing requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass A GFI protection: Detects ground-fault currents as low as 6 mA for personnel safety.\u003c\/li\u003e\n\u003cli\u003eTwo-pole design: Provides coordinated protection for single-phase 120 V circuits.\u003c\/li\u003e\n\u003cli\u003e30-amp rating: Supports moderate-load branch circuits in residential and commercial settings.\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip: Ensures accurate overload and instantaneous fault response.\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating: Capable of clearing standard fault levels at 120 volts.\u003c\/li\u003e\n\u003cli\u003ePlug-in mounting: Allows fast, secure installation in QO load centers.\u003c\/li\u003e\n\u003cli\u003eLI trip functions: Provides long-time and instantaneous protection modes.\u003c\/li\u003e\n\u003cli\u003eDurable molded case construction: Ensures long-term performance in varied environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe QO230GFI delivers the reliability and precision required for safeguarding single-phase electrical systems while providing critical Class A ground-fault protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":48553086189866,"sku":"QO230GFI","price":102.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/QO230GFI.jpg?v=1716806706","url":"https:\/\/iqelectro.com\/products\/schneider-electric-qo230gfi-circuit-breaker-responsive-support","provider":"IQElectro","version":"1.0","type":"link"}